Research Article

Numerical analysis of an air-conditioning energy-saving mechanism

K. David HuangNguyen Anh Tuan( )
Institute of Mechanical and Electrical Engineering, National Taipei University of Technology, 1, Sec. 3, Chung-Hsiao E. Rd., Taipei, 10608, Taiwan, China
Show Author Information

Abstract

This paper presents a new concept in energy-saving equipment, namely, a regional air-conditioning mechanism (RACM). The RACM system is constructed with an inlet and an outlet in a main duct centered in a cylindrical housing. The RACM produces an airflow circulation cell for satisfying the thermal comfort demands of users, and can potentially be energy-saving. This study targets two areas: (1) study the effect of cool air inlet velocity (Vinlet), negative outlet pressure (Pout), and distance between floor surface and outlet port (L2) of an airflow circulation cell, and (2) determine their suitable adjustments for creating a better method for using computational fluid dynamics (CFD). Experimental platforms were set up to test the validity of a simulation model, and the tested results showed good agreement with simulation. In the study, nine simulated case studies divided into three groups with various values of Vinlet, Pout, and L2 were analyzed. Case four of group two, Vinlet=0.3 m/s, Pout=-2 Pa, and L2=0.5 m, yielded the lowest energy consumption and the highest level of thermal comfort demands. Group one, in which Pout, and L2 were fixed for all case studies, except values of Vinlet, resulted in the most sensitive in terms of vertical temperature distribution along the body of a sedentary occupant in the room. The two thermal regions of the tested environment, i.e., occupied zone and the rest of the room, evidently experienced different temperatures in the simulated room. It was concluded that the RACM is a potential candidate for portable air-conditioning in enclosed spaces.

References

 
ASHRAE Inc. (2004). ASHRAE Handbook of Fundamentals, Chapter 8: Thermal Comfort. Atlanta, USA.
 
Bauman F, Baughman A, Carter G, Arens E (1997). A Field Study of PEM (Personal Environmental Module) Performance in Bank of America’s San Francisco Office Buildings, Center for the Built Environment, University of California, Berkeley.
 
Caddirey RJ (1988). The intelligent building—An ASHRAE opportunity. ASHRAE Transaction, 94(1): 925-933.
 
Faulkner D, Fish WJ, Sullivan DP, Wyon DP (1999). Ventilation efficiency of desk-mounted task/ambient conditioning systems. Indoor Air, 9: 273-281.
 
Fluent Inc. (2006). Fluent 6.3 User Guide. Lebanon, NH 03766, USA.
 
Huang KD, Tuan NA, Tseng KT (2008a). A numerical of regional air-conditioning mechanism. Paper presented at 2008 IEEE International Conference on Sustainable Energy Technologies, Singapore.
 
Huang KD, Tuan NA, Liu TC, Tseng KT (2008b). An air-conditioning energy-saving mechanism. Paper presented at the 19th international symposium on Transport Phenomena, Reykjavik, Iceland.
 
Huang KD, Tuan NA, Tseng KT (2009a). CFD study of an airconditioning energy-saving mechanism. Paper presented at the First International Conference on Applied Energy, HongKong.
 
Huang KD, Tuan NA, Shih YC (2009b). Energy-saving and thermal comfort studies of a regional air-conditioning mechanism. Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, doi: .
 
ISO 7730 (2005) Ergonomics of the thermal environment—Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria. International Organization for Standards, Geneva, Switzerland.
 
Kaczmarcryk J, Zeng Q, Melikov AK, Fanger PO (2002). Individual control and people’s preferences in an experiment with a personalized ventilation system. In: Proceedings of Ninth International Conference on Air Distribution in Rooms—Roomvent 2002, Copenhagen, Denmark, pp. 57-60.
 
Kaczmarcryk J (2003). Human response to personalized ventilation. PhD Thesis, Technical University of Denmark, Lyngby, Denmark.
Building Simulation
Pages 63-73
Cite this article:
Huang KD, Tuan NA. Numerical analysis of an air-conditioning energy-saving mechanism. Building Simulation, 2010, 3(1): 63-73. https://doi.org/10.1007/s12273-010-0302-y

613

Views

4

Crossref

N/A

Web of Science

5

Scopus

0

CSCD

Altmetrics

Received: 03 September 2009
Revised: 03 January 2010
Accepted: 04 January 2010
Published: 04 February 2010
© Tsinghua University Press and Springer-Verlag Berlin Heidelberg 2010
Return