1:50 scale modeling study on airflow effectiveness of large spaces mutually connected for underground workshops

Tong RenAngui Li( )Na LuoYing Zhang
School of Environmental and Municipal Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi 710055, China
Show Author Information

Abstract

In the design of air conditioning and ventilation for an underground workshop, such as hydropower station underground powerhouse, mechanical ventilation was frequently applied to control air quality for large and mutually connected spaces of Dynamo floor, Generatrix floor, Hydraulic floor and Cochlea floor. In this paper, based upon the similarity criterion, the dimensionless yield criterion was used to explore the airflow effectiveness of large spaces mutually connected and a 1:50 small-scale model of the main powerhouse was built which was used to study and analyze the airflow distribution in large spaces mutually connected. A series of parameters was obtained from the experiment, and here we discussed following conditions: three air supply velocities: V/V0=0.75, V/V0=1 and V/V0=1.25 (V0 is the designed air velocity in this model) and three heat release rates: Q/Q0=0.75, Q/Q0=1 and Q/Q0=1.25 (Q0 is the designed heat load in this model). The environmental parameters of a workspace at different floors were acquired to study the effect of mechanical ventilation on the temperature field under different air velocities and heat release rates. The experimental results show that the heat release rate had a significant effect on the main power house temperature distribution. An appropriate air supply velocity could effectively optimize workplace temperature distribution under high-heat intensity environment. Energy efficiency coefficient and non-uniform temperature coefficient were predicted and the optimal design parameters (0.75V0, 1Q0) were recommended after 9 kinds of tests were conducted. The experimental research is helpful to the ventilation design of large and mutually connected spaces, such as Dynamo, Generatrix, Hydraulic and Cochlea floors in hydropower station underground powerhouse.

References

 
D Abdullah (2015). Investigation of air quality in the underground and aboveground multi-storey car parks in terms of exhaust emissions. Procedia—Social and Behavioral Sciences, 195: 2601-2611.
 
X Chang, X Liu, W Zhou (2010). Hydropower in China at present and its further development. Energy, 11: 4400-4406.
 
C Dronkelaar, D Cóstola, R Mangkuto, J Hensen (2014). Heating and cooling energy demand in underground buildings: Potential for saving in various climates and functions. Energy and Buildings, 71: 129-136.
 
H Huang, R Ooka, N Liu, L Zhang, Z Deng, S Kato (2009). Experimental study of fire growth in a reduced-scale compartment under different approaching external wind conditions. Fire Safety Journal, 44: 311-321.
 
H Huang, Z Yan (2009). Present situation and future prospect of hydropower in China. Renewable and Sustainable Energy Reviews, 13: 1652-1656.
 
J Ho, H Xue, K Tay (2004). A field study on determination of carbon monoxide level and thermal environment in an underground car park. Building and Environment, 39: 67-75.
 
K Isao, U Kiyoshi, Y Yukio, Y Yasuo, M Tazuko (2006). A wind-tunnel study on exhaust gas dispersion from road vehicles Part I: Velocity and concentration fields behind single vehicles. Journal of Wind Engineering and Industrial Aerodynamics, 94: 639-658.
 
A Li, Z Liu, J Zhang, J Wang (2011). Reduced-scale model study of ventilation for large space of Generatrix floor in Hohhot underground hydropower station. Energy and Buildings, 43: 1003-1010.
 
A Li, E Qin, X Bao, G Wang, J Wang (2010). Experimental analysis on the air distribution of powerhouse of Hohhot hydropower station with 2D-PIV. Energy Conversion and Management, 42: 33-41.
 
A Li, P Tao, A Bao, Y Zhao (2013). PIV measurements of air distribution in a reduced-scale model—Ventilation of a busbar corridor in a hydropower station. International Journal of Ventilation, 12: 81-98.
 
S Liu, Z Tian, M Zhu, J Zhang, L An, P Liu (2008). Influence of air supply temperature on air distribution of connected large space buildings. Heating Ventilating & Air Conditioning, 38(2): 96-100. (in Chinese).
 
L Nicolas, F Xavier, I Christian, S Sandrine, R Laurent (2012). Reduced-scale study of wind influence on mean airflows inside buildings equipped with ventilation systems. Building and Environment, 58: 231-244.
 
L Nicolas, F Xavier, I Christian, S Sandrine, R Laurent (2013). Reduced-scale study of transient flows inside mechanically ventilated buildings subjected to wind and internal overpressure effects. Building and Environment, 62: 18-32.
 
Z Stamatis, D Argyro, K Panagiotis (2012). Analysis of conductive temperature variation due to multi-room underground interaction. Energy and Buildings, 55: 433-438.
 
P Tao, A Li, J Zhang, J Wang (2014). Scaling model study of the air distribution in a powerhouse under different ventilation conditions. Building Simulation, 7: 389-400.
 
A Widiatmojo, K Sasaki, N Widodo, Y Sugai, A Sahzabi, R Nguele (2016). Predicting gas dispersion in large scale underground ventilation: A particle tracking approach. Building and Environment, 95: 171-181.
 
W Wu, G Zhu, X Wang, G Zhang (2011). The comparative analysis of numerical simulation and experimental studies in large space building. Procedia Engineering, 11: 529-535.
 
Y Xiao, X Liu, R Zhang (2012). Calculation of transient heat transfer through the envelope of an underground cavern using Z-transfer coefficient method. Energy and Buildings, 48:190-198.
 
Q Yang (2006). Ventilation model experiment and numerical simulation study for Xilongchi hydropower station underground powerhouse. Master Dissertation, Chongqing University, China. (in Chinese)
 
Y Yu, X Li, W Shi (2009). A simplified model of heat and moisture transfer for tailrace tunnel ventilating in hydropower station. Applied Thermal Engineering, 29: 3254-3260.
 
Z Yuan, B Lei, K Ahmed (2013). Reduced-scale experimental research on fires in tunnels with natural ventilation. Procedia Engineering, 62: 907-915.
 
I Yüksel (2010). Hydropower for sustainable water and energy development. Renewable and Sustainable Energy Reviews, 14: 462-469.
Building Simulation
Pages 201-212
Cite this article:
Ren T, Li A, Luo N, et al. 1:50 scale modeling study on airflow effectiveness of large spaces mutually connected for underground workshops. Building Simulation, 2016, 9(2): 201-212. https://doi.org/10.1007/s12273-015-0258-z

620

Views

6

Crossref

N/A

Web of Science

7

Scopus

1

CSCD

Altmetrics

Received: 01 July 2015
Revised: 13 October 2015
Accepted: 19 October 2015
Published: 03 November 2015
© Tsinghua University Press and Springer-Verlag Berlin Heidelberg 2015
Return