AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Predicting integrated thermal and acoustic performance in naturally ventilated high-rise buildings using CFD and FEM simulation

Xiang Yu1Qide Zhang1Jian Kang2Fangsen Cui1( )
Institute of High Performance Computing, Agency for Science, Technology and Research (A*STAR), Singapore 138632
School of Architecture, University of Sheffield, Sheffield S10 2TN, UK
Show Author Information

Abstract

The study of ventilation windows for both natural ventilation and noise mitigation has drawn significant attention recently. This paper presents the numerical approaches to analyse the integrated thermal and acoustical performance of ventilation windows, for a residential building in tropical climate which employs double-layer noise mitigation window for natural ventilation. Given a set of outdoor wind conditions, the distributions of indoor flow and temperature fields are simulated using Computational Fluid Dynamics (CFD) model. The thermal comfort is evaluated using statistical Predicted Mean Vote (PMV) method. For the acoustic performance, noise radiation from road traffic is assumed as the noise source, and the sound insulation of building façade is simulated using Finite Element Method (FEM). From the simulation results, it is found that the thermal satisfaction response is closely related to the inlet wind temperature and speed, and the window opening size greatly affects the ventilation performance. From the case study in Singapore, during certain season, day/night time and with sufficient wind flow, the ventilation window can provide enough fresh air, maintain adequate thermal comfort and quiet acoustic environment for the occupants. The numerical approaches presented in this paper are applicable to general window design studies, and the simulation findings can be incorporated into green building planning. The advantages of using simulation approaches are highlighted and their limitations are discussed.

References

 
A Aflaki, N Mahyuddin, NA Mahmoud, MR Baharum (2015). A review on natural ventilation applications through building façade components and ventilation openings in tropical climates. Energy and Buildings, 101: 153–162.
 
ASHRAE (2007). 62.1.2007, Ventilation for Acceptable Indoor Air Quality. Atlanta, GA: American Society of Heating, Refrigerating and Air-Conditioning Engineers.
 
HB Awbi (2003). Ventilation of Buildings, 2nd edn. London: Taylor & Francis.
 
M Barclay, J Kang, S Sharples (2012). Combining noise mapping and ventilation performance for non-domestic buildings in an urban area. Building and Environment, 52: 68–76.
 
BCA (2015). Technical guide and requirements. Non-residential Buildings. Building & Construction Authority, Singapore.
 
C Bibby, M Hodgson (2013). Field measurement of the acoustical and airflow performance of interior natural-ventilation openings and silencers. Building and Environment, 67: 265–273.
 
C Bibby, M Hodgson (2014). Laboratory measurement of the acoustical and airflow performance of interior natural-ventilation openings and silencers. Applied Acoustics, 82: 15–22.
 
CK Bin, C Lee (2016). Urban Noise Management in Singapore. In: Proceedings of the 45th International Congress and Exposition of Noise Control Engineering (INTER-NOISE), Hamburg, Germany.
 
C Buratti, R Mariani, E Moretti (2011). Mean age of air in a naturally ventilated office: Experimental data and simulations. Energy and Buildings, 43: 2021–2027.
 
J Busch (1992). Thermal responses to the Thai office environment. ASHRAE Transactions, 96(1): 859–872.
 
RJ de Dear, KG Leow, SC Foo (1991). Thermal comfort in the humid tropics: Field experiments in air conditioned and naturally ventilated buildings in Singapore. International Journal of Biometeorology, 34: 259–265.
 
MHF De Salis, DJ Oldham, S Sharples (2002). Noise control strategies for naturally ventilated buildings. Building and Environment, 37: 471–484.
 
G Evola, V Popov (2006). Computational analysis of wind driven natural ventilation in buildings. Energy and Buildings, 38: 491–501.
 
PO Fanger (1970). Thermal Comfort: Analysis and Applications in Environmental Engineering. New York: McGraw Hill.
 
HE Feustel (1999). COMIS—An international multizone air-flow and contaminant transport model. Energy and Buildings, 30: 3–18.
 
A Flaga-Maryanczyk, J Schnotale, J Radon, K Was (2014). Experimental measurements and CFD simulation of a ground source heat exchanger operating at a cold climate for a passive house ventilation system. Energy and Buildings, 68: 562–570.
 
RD Ford, G Kerry (1973). The sound insulation of partially open double glazing. Applied Acoustics, 6: 57–72.
 
Franke J, Hellsten A, Schlünzen H, Carissimo B (2007). Best practice guideline for the CFD simulation of flows in the urban environment. Finnish Meteorological Institute.
 
H Huang, X Qiu, J Kang (2011). Active noise attenuation in ventilation windows. The Journal of the Acoustical Society of America, 130: 176–188.
 
Hurtley C (2009). Night Noise Guidelines for Europe. WHO Regional Office Europe.
 
ISO (2013). ISO717-1:2013, Acoustics—Rating of sound insulation in buildings and of building elements. Part 1: Airborne sound insulation.
 
J Kang, MW Brocklesby (2005). Feasibility of applying micro-perforated absorbers in acoustic window systems. Applied Acoustics, 66: 669–689.
 
Y Li, X Li (2015). Natural ventilation potential of high-rise residential buildings in northern China using coupling thermal and airflow simulations. Building Simulation, 8: 51–64.
 
CM Mak, WK Leung, GS Jiang (2010). Measurement and prediction of road traffic noise at different building floor levels in Hong Kong. Building Services Engineering Research and Technology, 31: 131–139.
 
DJ Oldham, X Zhao (1993). Measurement of the sound transmission loss of circular and slit-shaped apertures in rigid walls of finite thickness by intensimetry. Journal of Sound and Vibration, 161: 119–135.
 
R Ramponi, B Blocken (2012). CFD simulation of cross-ventilation for a generic isolated building: Impact of computational parameters. Building and Environment, 53: 34–48.
 
SD Ray, N-W Gong, LR Glicksman, JA Paradiso (2014). Experimental characterization of full-scale naturally ventilated atrium and validation of CFD simulations. Energy and Buildings, 69: 285–291.
 
SC Sekhar, SE Goh (2011). Thermal comfort and IAQ characteristics of naturally/mechanically ventilated and air-conditioned bedrooms in a hot and humid climate. Building and Environment, 46: 1905–1916.
 
Singapore (2017). Climate of Singapore. Meteorological Service Singapore.
 
P Sivakumar, HJ Palanthandalam-Madapusi, TQ Dang (2010). Control of natural ventilation for aerodynamic high-rise buildings. Building Simulation, 3: 311–325.
 
Søndergaard LS, Olesen HS (2012). Lydmæssig optimering af Russervinduer (Acoustical optimization of Supply Air Windows). Environmental project No. 1417, pp. 17–60.
 
S-K Tang (2017). A review on natural ventilation-enabling façade noise control devices for congested high-rise cities. Applied Sciences, 7(2): 175.
 
Y Tominaga, A Mochida, R Yoshie, H Kataoka, T Nozu, M Yoshikawa, T Shirasawa (2008). AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings. Journal of Wind Engineering and Industrial Aerodynamics, 96: 1749–1761.
 
Y Toparlar, B Blocken, P Vos, GJF van Heijst, WD Janssen, T van Hooff, H Montazeri, HJP Timmermans (2015). CFD simulation and validation of urban microclimate: A case study for Bergpolder Zuid, Rotterdam. Building and Environment, 83: 79–90.
 
N Trompette, J-L Barbry, F Sgard, H Nelisse (2009). Sound transmission loss of rectangular and slit-shaped apertures: Experimental results and correlation with a modal model. The Journal of the Acoustical Society of America, 125: 31–41.
 
NH Wong, H Feriadi, PY Lim, KW Tham, C Sekhar, KW Cheong (2002). Thermal comfort evaluation of naturally ventilated public housing in Singapore. Building and Environment, 37: 1267–1277.
 
X Yu, S-K Lau, L Cheng, F Cui (2017a). A numerical investigation on the sound insulation of ventilation windows. Applied Acoustics, 117: 113–121.
 
X Yu, Z Lu, L Cheng, F Cui (2017b). On the sound insulation of acoustic metasurface using a sub-structuring approach. Journal of Sound and Vibration, 401: 190–203.
 
C Zhou, Z Wang, Q Chen, Y Jiang, J Pei (2014). Design optimization and field demonstration of natural ventilation for high-rise residential buildings. Energy and Buildings, 82: 457–465.
Building Simulation
Pages 507-518
Cite this article:
Yu X, Zhang Q, Kang J, et al. Predicting integrated thermal and acoustic performance in naturally ventilated high-rise buildings using CFD and FEM simulation. Building Simulation, 2018, 11(3): 507-518. https://doi.org/10.1007/s12273-017-0423-7

574

Views

15

Crossref

N/A

Web of Science

17

Scopus

1

CSCD

Altmetrics

Received: 11 July 2017
Revised: 19 September 2017
Accepted: 26 October 2017
Published: 17 November 2017
© Tsinghua University Press and Springer-Verlag GmbH Germany 2017
Return