AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Multi-objective optimization of impinging jet ventilation systems: Taguchi-based CFD method

Samira Haghshenaskashani1Behrang Sajadi1( )Mathias Cehlin2
School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
Department of Building, Energy and Environmental Engineering, Faculty of Engineering and Sustainable Development, University of Gävle, Gävle, Sweden
Show Author Information

Abstract

This paper presents a Taguchi method-based approach that can optimize the operating performance of impinging jet ventilation (IJV) systems with limited computational fluid dynamics (CFD) simulation results. The Taguchi optimization calculation finds the best operating design for the weighted overall objective function as a presenter of the multi-objective function problem. The method is used to optimize the operating characteristics of an IJV system considering the factors of supply air temperature, level of the return air vent and percentage of the air exhausted through the ceiling to achieve an overall best performance of thermal comfort, indoor air quality (IAQ) and system energy performance as the objective functions. The study indicates the contribution percentage for each factor in each objective function. The level of the return air vent, the supply air temperature, and the percentage of air exhausted through the ceiling have a contribution of 35.8%, 28.5%, and 35.8% in the objective functions, respectively. Based on the results, the best performance of the IJV system happens when the inlet air temperature is 18 °C, the height of the return air vent is 2 m above the floor, and the percentage of air exhausted through the ceiling is 22.5%.

References

 
ANSYS (2007). ANSYS Airpak 3.0. User’s guide. Canonsburg, PA: ANSYS.
 
ASHRAE (2010). ASHRAE 55: Standard Thermal Environmental Conditions for Human Occupancy. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers.
 
M Bojic, F Yik, TY Lo (2002). Locating air-conditioners and furniture inside residential flats to obtain good thermal comfort. Energy and Buildings, 34: 745–751.
 
GEP Box, DW Behnken (1960). Some new three level designs for the study of quantitative variables. Technometrics, 2: 455–475.
 
R Chauhan, T Singh, N Kumar, A Patnaik, NS Thakur (2017). Experimental investigation and optimization of impinging jet solar thermal collector by Taguchi method. Applied Thermal Engineering, 116: 100–109.
 
H Chen (2014). Experimental and numerical investigations of a ventilation strategy—Impinging jet ventilation for an office environment. PhD Thesis, Linköping University, Sweden.
 
H Chen, B Moshfegh, M Cehlin (2013a). Computational investigation on the factors influencing thermal comfort for impinging jet ventilation. Building and Environment, 66: 29–41.
 
H Chen, B Moshfegh, M Cehlin (2013b). Investigation on the flow and thermal behavior of impinging jet ventilation systems in an office with different heat loads. Building and Environment, 59: 127–144.
 
HJ Chen, B Moshfegh, M Cehlin (2012). Numerical investigation of the flow behavior of an isothermal impinging jet in a room. Building and Environment, 49: 154–166.
 
S Haghshenaskashani, B Sajadi (2018). Evaluation of thermal comfort, IAQ and energy consumption in an impinging jet ventilation (IJV) system with/without ceiling exhaust. Journal of Building Engineering, 18: 142–153.
 
M Huang (2007). A primer on Taguchi Method. University of San Diego, USA.
 
T Karimipanah, HB Awbi (2002). Theoretical and experimental investigation of impinging jet ventilation and comparison with wall displacement ventilation. Building and Environment, 37: 1329–1342.
 
Karimipanah T, Sandberg M, Awbi HB (2000). A comparative study of different air distribution systems in a classroom. In: Proceedings of the 7th International Conference on Air Distribution in Rooms, Reading, UK, pp. 10131018.
 
K Lee, G Xue, Z Jiang, Q Chen (2012). Thermal environment in indoor spaces with under-floor air distribution systems: Part 1. Impact of design parameters (1522-RP). HVAC&R Research, 18: 1182–1191.
 
Z Lian, H Wang (2002). Experimental study of factors that affect thermal comfort in an upward-displacement air-conditioned room. HVAC&R Research, 8: 191–200.
 
ID Metzger (2007). Design and optimization of personalized ventilation for overall improvement of thermal comfort, air quality, and energy efficiency. University of San Diego, USA.
 
ID Metzger (2012). Taguchi-method-based CFD study and optimisation of personalised ventilation systems. Indoor and Built Environment, 21: 690–702.
 
KC Ng, K Kadirgama, EYK Ng (2008). Response surface models for CFD predictions of air diffusion performance index in a displacement ventilated office. Energy and Buildings, 40: 774–781.
 
T Norton, J Grant, R Fallon, DW Sun (2010). Optimising the ventilation configuration of naturally ventilated livestock buildings for improved indoor environmental homogeneity. Building and Environment, 45: 2010.
 
B Sajadi, MH Saidi, A Mohebbian (2011). Numerical investigation of the swirling air diffuser: Parametric study and optimization. Energy and Buildings, 43: 1329–1333.
 
G Taguchi, J Rajesh (2000). New trends in multivariate diagnosis. Indian Journal of Statistics, 62: 233–248.
 
G Taguchi, S Chowdhury, Y Wu (2005). Taguchi’s Quality Engineering Handbook. Hoboken, NJ, USA: John Wiley & Sons.
 
X Ye, H Zhu, Y Kang, K Zhong (2016). Heating energy consumption of impinging jet ventilation and mixing ventilation in large-height spaces: A comparison study. Energy and Buildings, 130: 697–708.
 
Z Zhai, ID Metzger (2012). Taguchi-method-based CFD study and optimisation of personalised ventilation systems. Indoor and Built Environment, 21: 690–702
Building Simulation
Pages 1207-1214
Cite this article:
Haghshenaskashani S, Sajadi B, Cehlin M. Multi-objective optimization of impinging jet ventilation systems: Taguchi-based CFD method. Building Simulation, 2018, 11(6): 1207-1214. https://doi.org/10.1007/s12273-018-0450-z

657

Views

24

Crossref

N/A

Web of Science

21

Scopus

6

CSCD

Altmetrics

Received: 04 December 2017
Revised: 05 April 2018
Accepted: 19 April 2018
Published: 16 May 2018
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2018
Return