AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Development of a procedure for estimating the parameters of mechanistic VOC emission source models from chamber testing data

Zhenlei Liu1Andreas Nicolai2Marc Abadie3Menghao Qin4John Grunewald2Jianshun Zhang1,5( )
Department of Mechanical and Aerospace Engineering, Syracuse University, USA
Dresden University of Technology, Germany
University of La Rochelle, France
Technical University of Denmark, Denmark
School of Architecture and Urban Planning, Nanjing University, China
Show Author Information

Abstract

In order to evaluate the impacts of volatile organic compounds (VOCs) emissions from building materials on the indoor air quality beyond the standard chamber test conditions and test period, mechanistic emission source models have been developed in the past. However, very limited data are available for the required model parameters including the initial concentration (Cm0), in-material diffusion coefficient (Dm), partition coefficient (Kma), and convective mass transfer coefficient (km). In this study, a procedure was developed for estimating the model parameters by using VOC emission data from standard small chamber tests. In the procedure, initial values of the model parameters were refined by multivariate regression analysis of the measured emission data. To verify the procedure and estimate its uncertainty, simulated chamber test data were generated by adding 10% experimental uncertainties on the theoretical curve from the analytical solution to a mechanistic emission model. Then the procedure was applied to the generated data to estimate the model parameters. Results indicated that estimates converged to the original parameter values used for the data generation and the error of estimated parameters Dm, Cm0 and Kma were within ±10%, ±23%, and ±25% of the true values, respectively. The procedure was further demonstrated by applying it to estimate the model parameters from real chamber test data. Wide application of the procedure would result in a database of mechanistic source model parameters for assessing the impact of VOC emissions on indoor pollution load, which are essential input data for evaluating the effectiveness of various indoor air quality (IAQ) design and control strategies as well as the energy required for meeting given IAQ requirements.

Electronic Supplementary Material

Download File(s)
12273_2020_616_MOESM1_ESM.pdf (791.7 KB)

References

 
Bodalal A (1999). Fundamental mass transfer modeling of emission of volatile organic compounds from building materials. PhD Thesis, Carleton University, USA.
 
Cox SS, Zhao D, Little JC(2001). Measuring partition and diffusion coefficients for volatile organic compounds in vinyl flooring. Atmospheric Environment, 35: 3823-3830.
 
Deng B, Kim CN(2004). An analytical model for VOCs emission from dry building materials. Atmospheric Environment, 38: 1173-1180.
 
He G, Yang X(2005). On regression method to obtain emission parameters of building materials. Building and Environment, 40: 1282-1287.
 
He G, Yang X, Shaw CY(2005). Material emission parameters obtained through regression. Indoor and Built Environment, 14: 59-68.
 
Huang H, Haghighat F(2002). Modelling of volatile organic compounds emission from dry building materials. Building and Environment, 37: 1349-1360.
 
ISO (2011). Indoor Air—Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID, Standard. Geneva: International Organization for Standardization.
 
Little JC, Hodgson AT, Gadgil AJ(1994). Modeling emissions of volatile organic compounds from new carpets. Atmospheric Environment, 28: 227-234.
 
Magee R, Zhu J, Zhang J, Shaw C (1999). A small chamber test method for measuring volatile organic compound emission from “dry” building materials. Final report 1.2 of consortium for material emission and IAQ modelling (CMEIAQ) 1999, Institute for Research in Construction, NRC, Canada.
 
Qian K, Zhang Y, Little JC, Wang X(2007). Dimensionless correlations to predict VOC emissions from dry building materials. Atmospheric Environment, 41: 352-359.
 
Rode C, Abadie M, Qin M, Grunewald J, Kolarik J, Laverge J (2016). IEA project on indoor air quality design and control in low energy residential buildings. In: Proceedings of the 12th REHVA World Congress.
 
White F(1988). Heat and Mass Transfer., Reading, MA: Addison-Wesley.
 
Xiong J, Yao Y, Zhang Y(2011). C-history method: rapid measurement of the initial emittable concentration, diffusion and partition coefficients for formaldehyde and VOCs in building materials. Environmental Science & Technology, 45: 3584-3590.
 
Xiong J, Huang S, Zhang Y(2012). A novel method for measuring the diffusion, partition and convective mass transfer coefficients of formaldehyde and VOC in building materials. PLoS One, 7: e49342.
 
Xiong J, Wang L, Bai Y, Zhang Y(2013). Measuring the characteristic parameters of VOC emission from paints. Building and Environment, 66: 65-71.
 
Xu J, Zhang JS(2011). An experimental study of relative humidity effect on VOCs’ effective diffusion coefficient and partition coefficient in a porous medium. Building and Environment, 46: 1785-1796.
 
Yang X, Chen Q, Zhang J, Magee R, Zeng J, Shaw C(2001). Numerical simulation of VOC emissions from dry materials. Building and Environment, 36: 1099-1107.
 
Zhang JS, Shaw C (1997). Modelling of volatile organic compound (VOC) emissions from building materials/furnishings: A literature review. IRC/NRC Internal Research Report. National Research Council of Canada.
 
Zhang JS, Zhu JP, Shaw CY, Zeng J, Plett EG, Bodalal A, Chen Q, Yang X (1999). Development of standard small chamber test methods.
 
Zhang Y, Xu Y(2003). Characteristics and correlations of VOC emissions from building materials. International Journal of Heat and Mass Transfer, 46: 4877-4883.
 
Zhang J, Zhang JS, Chen Q(2003). Effects of Environmental Conditions on the Sorption of VOCs on Building Materials—Part II : Model Evaluation. ASHRAE Transactions, 109(1): 167-178.
 
Zhang J, Li H, Zhang Z, Salonvaara M (2006). On the power-law model for predicting the VOC emissions from office workstation systems. In: Proceedings of the A and WMA Indoor Environmental Quality: Problems, Research and Solutions Conference, Durham, NC, USA.
 
Zhou X, Liu Y, Liu J(2018). Alternately airtight/ventilated emission method: A universal experimental method for determining the VOC emission characteristic parameters of building materials. Building and Environment, 130: 179-189.
 
Zhu J, Magee R, Lusztyk E, Zhang J, Shaw C (1999). Material emission data for typical building materials: Small environmental chamber test. Final report 4.1 of consortium for material emission and IAQ modelling (CMEIAQ) 1999, Institute for Research in Construction, NRC, Canada.
 
Zhu J, Zhang J, Shaw C(2001). Comparison of models for describing measured VOC emissions from wood-based panels under dynamic chamber test condition. Chemosphere, 44: 1253-1257.
Building Simulation
Pages 269-282
Cite this article:
Liu Z, Nicolai A, Abadie M, et al. Development of a procedure for estimating the parameters of mechanistic VOC emission source models from chamber testing data. Building Simulation, 2021, 14(2): 269-282. https://doi.org/10.1007/s12273-020-0616-3

623

Views

18

Crossref

N/A

Web of Science

19

Scopus

1

CSCD

Altmetrics

Received: 17 November 2019
Accepted: 02 February 2020
Published: 11 March 2020
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2020
Return