AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Assessment of factors influencing the energy and water performance of aquatic centres

Jean Jonathan Duverge( )Priyadarsini Rajagopalan
RMIT University, Swanston Street, Melbourne, Australia
Show Author Information

Abstract

Aquatic centres are unlike any other type of buildings in terms of energy and water consumption. Aquatic centres can expend around seven times more energy for every square metre of building area compared to an average commercial office building and consume as much as 1,000 million litres of water each year. There has been insufficient research that examines the energy performance and water usage of aquatic centres worldwide compared to other types of buildings. Also, there are very limited studies that modelled an entire aquatic centre that has multiple indoor pools within a pool hall. The main difficulty is to model the interaction of water evaporation with the mechanical equipment which is not able to be controlled by most of the energy modelling software. Using the indoor swimming pool module integrated into the surface heat balance procedures in EnergyPlus 8.7, this paper investigates the factors that influence the energy and water performance of an aquatic centre in Victoria, Australia. Detailed information about the building envelope, electromechanical systems and operational data have been obtained from the aquatic centre. The model is calibrated against measured energy and water data (utility bills obtained from the aquatic centre). Parametric studies of several energy and water efficient features are undertaken. The simulation results revealed that the incorporation of solar pool-heating systems resulted in 15.4% energy reduction and the use of vacuum filters for backwash water usage resulted in 20% water reduction. Through creating detailed procedures and processes, this paper demonstrates that an aquatic centre can be modelled successfully despite its noted complexity.

References

 
ASHRAE (1995). Application Handbook (SI), Chapter 4: Natatoriums. Atlanta, GA, USA: American Society of Heating, Refrigeration and Air-Conditioning Engineers.
 
ASHRAE (1999). HVAC Application Handbook, Chapter 48: General applications—Swimming pools/health clubs. Atlanta, GA, USA: American Society of Heating, Refrigeration and Air-Conditioning Engineers.
 
Auer T (1996). TRNSYS-TYPE 344: Assessment of an indoor or outdoor swimming pool. Available at http://www.transsolar.com/software/download/en/ts_type_344_en.pdf. Accessed 26 August 2014.
 
Barbato M, Cirillo L, Menditto L, Moretti R, Nardini S (2018). Feasibility study of a geothermal energy system for indoor swimming pool in Campi Flegrei area. Thermal Science and Engineering Progress, 6: 421-425.
 
Costa A, Garay RS, Messervey T, Keane, MM (2011).Value of building simulation in sport facilities operation. In: Proceedings of the 12th International IBPSA Building Simulation Conference, Sydney, Australia, pp. 664-671.
 
Delgado Marín JP, Vera García F, García Cascales JR (2019). Use of a predictive control to improve the energy efficiency in indoor swimming pools using solar thermal energy. Solar Energy, 179: 380-390.
 
Department of the Environment and Energy (2017). Australian national greenhouse accounts factors: Australian national greenhouse accounts. Available at http://www.environment.gov.au/system/files/resources/5a169bfb-f417-4b00-9b70-6ba328ea8671/files/national-greenhouse-accounts-factors-july-2017.pdf. Accessed 21 May 2018
 
Duverge JJ, Rajagopalan P, Fuller R (2017). Defining aquatic centres for energy and water benchmarking purposes. Sustainable Cities and Society, 31: 51-61.
 
ECORYS (2014). Resource efficiency in the building sector. Copenhagen Resource Institute. Available at http://ec.europa.eu/environment/eussd/pdf/Resource%20efficiency%20in%20the%20building%20sector.pdf. Accessed 10 May 2017.
 
EnergyPlus (2015). EnergyPlus Documentation: Technical Manual.
 
Harish VSKV, Kumar A (2016). A review on modeling and simulation of building energy systems. Renewable and Sustainable Energy Reviews, 56: 1272-1292.
 
IEA (2013). IEA online data services. International Energy Agency. Available at https://www.iea.org/statistics/onlinedataservice. Accessed 1 May 2015.
 
Kaci K, Merzouk M, Merzouk NK, El Ganaoui M, Sami S, Djedjig R (2017). Dynamic simulation of hybrid-solar water heated Olympic swimming pool. Energy Procedia, 139: 750-757.
 
Kenna E, Bannister P (2009). Simple, fully featured boiler loop modelling. In: Proceedings of the 11thInternational IBPSA Building Simulation Conference, Glasgow, UK.
 
Lucon O, Ürge-Vorsatz D, Zain Ahmed A, Akbari H, Bertoldi P, et al. (2014). Climate change 2014: mitigation of climate change. Contribution of Working Group III to the Fifth Assessment Report of the Intergovernmental Panel on Climate Change. Available at http://www.ipcc.ch/pdf/assessment-report/ar5/wg3/ipcc_wg3_ar5_chapter9.pdfpp.671-738. Accessed 18 Mar 2015
 
Mancic MV, Zivkovic D, Milosavljevic P, Todorovic M (2014). Mathematical modelling and simulation of the thermal performance of a solar heated indoor swimming pool. Thermal Science, 18: 999-1010.
 
Ribeiro E, Jorge HM, Quintela DA (2011). HVAC system energy optimization in indoor swimming pools. In: Proceedings of the 3rd International Youth Conference on Energetics (IYCE), Leiria, Portugal.
 
Sengupta AR, Biswas A, Gupta R (2017).Vertical axis wind turbines in the built environment—A review. ISESCO Journal of Science and Technology, 12 (22): 11-16.
 
Shah MM (2002). Rate of evaporation from undisturbed water pools: Evaluation of available correlations. International Journal of HVAC&R Research, 8: 125-132.
 
Sydney Water (2011). Best practice guidelines for water management in aquatic leisure centres. Sydney Water Corporation. Available at https://www.sydneywater.com.au/web/groups/publicwebcontent/documents/document/zgrf/mdq1/~edisp/dd_045262.pdf. Accessed 25 Aug 2014.
 
Trianti-Stourna E, Spyropoulou K, Theofylaktos C, Droutsa K, Balaras CA, et al. (1998). Energy conservation strategies for sports centers: Part B. Swimming pools. Energy and Buildings, 27: 123-135.
 
UNEP (2009). Building and climate change: Summary for decision-makers. United Nations Environment Program. Available at https://europa.eu/capacity4dev/unep/document/buildings-and-climate-change-summary-decision-makers. Accessed 17 Mar 2015.
 
UNEP (2016). Global roadmap: Towards low-GHG and resilient buildings. United Nations Environment Program. Available at http://www.globalabc.org/uploads/media/default/0001/01/0d6a71a346ea7e6841b1b29c77eba6d6ae986103.pdf. Accessed 12 September 2017.
Building Simulation
Pages 771-786
Cite this article:
Duverge JJ, Rajagopalan P. Assessment of factors influencing the energy and water performance of aquatic centres. Building Simulation, 2020, 13(4): 771-786. https://doi.org/10.1007/s12273-020-0644-z

604

Views

4

Crossref

N/A

Web of Science

4

Scopus

0

CSCD

Altmetrics

Received: 27 November 2019
Accepted: 07 April 2020
Published: 13 June 2020
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2020
Return