AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Airflow pattern and performance of attached ventilation for two types of tiny spaces

Haiguo Yin1,2,3( )Yanyan Li1Da Zhang4Yuekun Han1Jiali Wang1Yongshou Zhang2,3Angui Li1
School of Building Services Science and Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, Shaanxi, China
The key Lab of Plateau Building and Eco-community in Qinghai, Xining 810008, Qinghai, China
Qinghai Building and Materials Research Co., Ltd, Xining 810008, Qinghai, China
Energy Engineering Design Institute, Energy and Environmental Engineering Research Institute, China IPPR International Engineering Co., Ltd., Beijing, China
Show Author Information

Abstract

With the emergence of urban sentry boxes and capsule hotels, the development of tiny spaces with the concept of a reasonable minimum occupied space has attracted widespread attention from society. The ventilation mode that fits with the limited geometric characteristics of tiny spaces is worth exploring. Combined with the respective ventilation requirements of two types of tiny spaces, i.e., sentry box space and tiny sleeping space, this paper proposes two attached ventilation modes. A full-scale experiment cabin was established, and the simulation method was optimized through experimental data. The airflow pattern and distribution performance of the two attached ventilation modes in two types of tiny spaces were studied by the CFD method. The results showed that the airflow attached to the vertical wall could form an air curtain at the opening windows of the sentry box space, but there is a phenomenon of air leakage. The installation of the deflector can improve the integrity of the air curtain, and the best installation angle of the deflector is 60 degrees. The double side-attached ventilation mode in the tiny sleeping space can not only relieve the draught of the occupants (DR < 15%), but also firstly deliver fresh air to the occupied zone (expiratory zone MAA < 92 s). The research conclusions will add new ideas to the diversity of ventilation modes in tiny spaces.

References

 
ASHRAE (2017). ANSI/ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy. Atlanta: American Society of Heating, Refrigerating, and Air-conditioning Engineers.
 
Awbi HB (1991). Ventilation of Buildings. London: Routledge.
 

Boscoianu M, Prisecariu V, Cîrciu I (2010). Applications and com­putational aspects regarding the Coanda effect. Science & Military Journal, 5: 26–30.

 

Canha N, Lage J, Candeias S, et al. (2017). Indoor air quality during sleep under different ventilation patterns. Atmospheric Pollution Research, 8: 1132–1142.

 

Cao G, Ruponen M, Kurnitski J (2010). Experimental investigation of the velocity distribution of the attached plane jet after impingement with the corner in a high room. Energy and Buildings, 42: 935–944.

 

Cao G, Awbi H, Yao R, et al. (2014). A review of the performance of different ventilation and airflow distribution systems in buildings. Building and Environment, 73: 171–186.

 

Chen Q (1995). Comparison of different kε models for indoor air flow computations. Numerical Heat Transfer, Part B: Fundamentals, 28: 353–369.

 

Chen Q, Srebric J (2002). A procedure for verification, validation, and reporting of indoor environment CFD analyses. HVAC & R Research, 8: 201–216.

 

Chen C, Zhao B, Yang X (2011). Preventing the entry of outdoor particles with the indoor positive pressure control method: Analysis of influencing factors and cost. Building and Environment, 46: 1167–1173.

 

Chiang C (2018). Influences of price, service convenience, and social service scape on post-purchase process of capsule hotels. Asia Pacific Journal of Tourism Research, 23: 373–384.

 

Cho Y, Awbi HB, Karimipanah T (2008). Theoretical and experimental investigation of wall confluent jets ventilation and comparison with wall displacement ventilation. Building and Environment, 43: 1091–1100.

 
Coanda H (1936). Device for deflecting a stream of elastic fluid projected into an elastic fluid. US Patent, US1736135A, 1936-9-1.
 
Cole SE, Heber AJ, Murphy JP (1988). Benefits of deflector for ventilation fans in direct winds. American Society of Agricultural Engineers (Microfiche collection) (USA), Issue: fiche88-4536, 25.
 

Du J, Chan M, Pan D, et al. (2017). A numerical study on the effects of design/operating parameters of the radiant panel in a radiation-based task air conditioning system on indoor thermal comfort and energy saving for a sleeping environment. Energy and Buildings, 151: 250–262.

 

Fan J, Wu L, Zhang F, et al. (2018). Evaluating the effect of air pollution on global and diffuse solar radiation prediction using support vector machine modeling based on sunshine duration and air temperature. Renewable and Sustainable Energy Reviews, 94: 732–747.

 
Fragkou D, Stevenson E V (2012). Study of Beehive and its potential "biomimicry" application on capsule hotels in Tokyo, Japan. In: Proceedings of the 2nd Conference of People and Buildings, London, UK.
 
ISO (2005). BS EN ISO 7730-2005: Ergonomics of the Thermal Environment-Analytical Determination and Interpretation of Thermal Comfort Using Calculation of the PMV and PPD Indices and Local Thermal Comfort Criteria. Geneva: International Organization for Standardization.
 
Jablonska J, Tarczewski R, Trocka-Leszczynska E (2017). Ergonomic Solutions in Capsule Hotels? In: Proceedings of the International Conference on Applied Human Factors and Ergonomics, Los Angeles, USA. https://doi.org/10.1007/978-3-319-60450-3_23
 

Karimipanah T, Awbi HB (2002). Theoretical and experimental investigation of impinging jet ventilation and comparison with wall displacement ventilation. Building and Environment, 37: 1329–1342.

 

Lan L, Lian Z, Zhou X, et al. (2013). Pilot study on the application of bedside personalized ventilation to sleeping people. Building and Environment, 67: 160–166.

 

Lee WS, Lee JK, Moon J (2018). Study on the preference for capsule hotel attributes using a choice experiment. Tourism Economics, 24: 492–499.

 

Lemy DM, Heidi E (2019). The potential of capsule hotel service in Semarang. E-Journal of Tourism, 196.

 

Li D, Li X, Yang X, et al. (2003). Total air age in the room ventilated by multiple air-handling units: Part 1: An algorithm. ASHRAE Transactions, 109: 829–836.

 

Li A, Yi H, Zhang W (2012). A novel air distribution method— Principles of air curtain ventilation. International Journal of Ventilation, 10: 383–390.

 

Li A, Li M (2016). Research on the effectiveness of air curtain ventilation air distribution for small micro-space. Journal of Xi'an University of Architecture & Technology (Natural Science Edition), 48: 115–121. (in Chinese)

 

Li A, Liu W, Yao C, et al. (2016). CFD and the experimental study of air distribution in the breathing zone based on air curtain ventilation with deflector. Journal of Xi'an University of Architecture & Technology (Natural Science Edition), 48: 738–744.

 

Li A (2019). Extended Coanda Effect and attachment ventilation. Indoor and Built Environment, 28: 437–442.

 

Liao C, Akimoto M, Bivolarova MP, et al. (2021). A survey of bedroom ventilation types and the subjective sleep quality associated with them in Danish housing. Science of the Total Environment, 798: 149209.

 

Lin Z, Deng S (2008). A study on the thermal comfort in sleeping environments in the subtropics—Developing a thermal comfort model for sleeping environments. Building and Environment, 43: 70–81.

 

Lin Z, Tian L, Yao T, et al. (2011). Experimental and numerical study of room airflow under stratum ventilation. Building and Environment, 46: 235–244.

 

Liu W, Lian Z, Deng Q, et al. (2011). Evaluation of calculation methods of mean skin temperature for use in thermal comfort study. Building and Environment, 46: 478–488.

 

Luo Z, Wang Z, Wang H, et al. (2021). Characterizing spatiotemporal distributions of black carbon and PM2.5 at a toll station: Observations on manual and electronic toll collection lanes. Building and Environment, 199: 107933.

 

Mao N, Hao J, Cui B, et al. (2018a). Energy performance of a bedroom task/ambient air conditioning (TAC) system applied in different climate zones of China. Energy, 159: 724–736.

 

Mao N, Zhang B, Song M, et al. (2018b). A simplified numerical study on the energy performance and thermal environment of a bedroom TAC system. Energy and Buildings, 166: 305–316.

 

Mitchell D, Wyndham CH (1969). Comparison of weighting formulas for calculating mean skin temperature. Journal of Applied Physiology, 26: 616–622.

 

Moureh J, Flick D (2004). Airflow pattern and temperature distribution in a typical refrigerated truck configuration loaded with pallets. International Journal of Refrigeration, 27: 464–474.

 

Ntinas GK, Shen X, Wang Y, et al. (2018). Evaluation of CFD turbulence models for simulating external airflow around varied building roof with wind tunnel experiment. Building Simulation, 11: 115–123.

 

Olesen BW, Fanger PO (1973). The skin temperature distribution for resting man in comfort. Archives Des Sciences Physiologiques, 27: 385–393.

 

Raithby GD, Chui EH (1990). A finite-volume method for predicting a radiant heat transfer in enclosures with participating media. Journal of Heat Transfer, 112: 415–423.

 
Rossano AT, Alsid HF (1972). Evergreen point bridge toll booth ventilation study. Air resource program, University of Washington, USA.
 

Sandberg M, Sjöberg M (1983). The use of moments for assessing air quality in ventilated rooms. Building and Environment, 18: 181–197.

 

Sapkota A, Williams D, Buckley TJ (2005). Tollbooth workers and mobile source-related hazardous air pollutants: how protective is the indoor environment? Environmental Science & Technology, 39: 2936–2943.

 

Shirzadi M, Mirzaei PA, Tominaga Y (2020). CFD analysis of cross- ventilation flow in a group of generic buildings: Comparison between steady RANS, LES and wind tunnel experiments. Building Simulation, 13: 1353–1372.

 

Sun C, Zhang J, Guo Y, et al. (2018). Outdoor air pollution in relation to sick building syndrome (SBS) symptoms among residents in Shanghai, China. Energy and Buildings, 174: 68–76.

 

Tsai PJ, Shih TS, Chen HL, et al. (2004). Assessing and predicting the exposures of polycyclic aromatic hydrocarbons (PAHs) and their carcinogenic potencies from vehicle engine exhausts to highway toll station workers. Atmospheric Environment, 38: 333–343.

 

Van Hooff T, Blocken B, Timmermans HJP, et al. (2016). Analysis of the predicted effect of passive climate adaptation measures on energy demand for cooling and heating in a residential building. Energy, 94: 811–820.

 

Wang Z, Guo X, Pan X, et al. (2020). Numerical simulation of hybrid ventilation for underground subway depot with superstructures. International Journal of Ventilation, 19: 280–299.

 
Yang B, He Y, Wang S, et al. (2014). Personalized environmental control system for highway toll booths. China patent, ZL201210204756.9, 2014-7-30. (in Chinese)
 
Yang H, Qi C, Liu L, et al. (2010). Experimental study on indoor environment improvement in toll booth by personalized ventilation technology. Journal of Southeast University (English Edition), 26: 307–310.
 

Yin H, Li A (2016). Study of attached air curtain ventilation within a full-scale enclosure: comparison of four turbulence models. Indoor and Built Environment, 25: 962–975.

 

Yin H, Huo Y, Wang Y, et al. (2021a). Numerical investigation on mechanisms and performance of column attachment ventilation for winter heating. Building and Environment, 202: 108025.

 

Yin H, Li L, Wu R, et al. (2021b). A numerical study on the effect of column layout on air distribution and performance of column attachment ventilation. Building Simulation, 14: 1095–1108.

 

Yu H, Akita T (2019). The effect of illuminance and correlated colour temperature on perceived comfort according to reading behaviour in a capsule hotel. Building and Environment, 148: 384–393.

 

Zhou X, Lian Z, Lan L (2014). Experimental study on a bedside personalized ventilation system for improving sleep comfort and quality. Indoor and Built Environment, 23: 313–323.

 

Zhang Y, Li J, Sun H, et al. (2015). Evaluation of different air distribution systems for sleeping spaces in transport vehicles. Building and Environment, 94: 665–675.

 

Zhang X, Luo G, Xie J, et al. (2021). Associations of bedroom air temperature and CO2 concentration with subjective perceptions and sleep quality during transition seasons. Indoor Air, 31: 1004–1017.

Building Simulation
Pages 1491-1506
Cite this article:
Yin H, Li Y, Zhang D, et al. Airflow pattern and performance of attached ventilation for two types of tiny spaces. Building Simulation, 2022, 15(8): 1491-1506. https://doi.org/10.1007/s12273-021-0876-6

721

Views

8

Crossref

8

Web of Science

8

Scopus

0

CSCD

Altmetrics

Received: 30 September 2021
Revised: 23 November 2021
Accepted: 15 December 2021
Published: 06 January 2022
© Tsinghua University Press 2022
Return