AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Analysis of COVID-19 clusters involving vertical transmission in residential buildings in Hong Kong

Department of Mechanical Engineering, The University of Hong Kong, Pokfulam, Hong Kong, China
Show Author Information

Abstract

Multiple clusters of coronavirus disease 2019 (COVID-19) in Hong Kong have involved vertical transmissions in residential buildings, wherein the flats of confirmed cases were often vertically aligned. Data on the buildings and cases associated with 19 such clusters were retrieved and compared with the corresponding data on the entirety of Hong Kong. Vertical transmissions usually occurred in old high-rise buildings with small flat areas and low estate prices during winter. In addition, infection occurred frequently among the elderly and among upstairs neighbours of index cases. Virus-laden aerosols may have been transmitted between flats mostly via shared drainpipes, and the vertical distribution of the confirmed cases in a building varied by its drainage system design. For buildings with their entire drainpipes installed indoors, both the upstairs and downstairs neighbours of the index case flats could be infected. By comparison, buildings with their drainage stacks installed outdoors had lower infection risks and demonstrated a clearer pattern of vertical transmission: most infected cases resided upstairs from the index case flats, indicating that the virus spread could be dominated by the stack effect. This study provides valuable data and analysis for developing epidemic control strategies for residential buildings.

Electronic Supplementary Material

Download File(s)
bs-16-5-701_ESM.pdf (621.8 KB)

References

 

Achakji G, Tamura GT (1988). Pressure drop characteristics of typical stairshafts in high-rise buildings. ASHRAE Transactions, 94(1): 1223–1237.

 

Ainsworth BE, Haskell WL, Whitt MC, et al. (2000). Compendium of Physical Activities: an update of activity codes and MET intensities. Medicine and Science in Sports and Exercise, 32: S498–S516.

 

Bao L, Gao H, Deng W, et al. (2020). Transmission of severe acute respiratory syndrome coronavirus 2 via close contact and respiratory droplets among human angiotensin-converting enzyme 2 mice. The Journal of Infectious Diseases, 222(4): 551–555.

 

Cheng VC, Wong SC, Au AK, et al. (2022). Explosive outbreak of SARS-CoV-2 Omicron variant is associated with vertical transmission in high-rise residential buildings in Hong Kong. Building and Environment, 221: 109323.

 
Cole M (2015). Hong Kong leads list of biggest housing bubbles. https://www.mingtiandi.com/real-estate/research-policy/hong-kong-and-london-lead-list-of-worlds-biggest-housing-bubbles/. Accessed 1 Apr 2022.
 

Dai H, Zhao B (2020). Association of the infection probability of COVID-19 with ventilation rates in confined spaces. Building Simulation, 13: 1321–1327.

 

Desai PS, Sawant N, Keene A (2021). On COVID-19-safety ranking of seats in intercontinental commercial aircrafts: A preliminary multiphysics computational perspective. Building Simulation, 14: 1585–1596.

 
Du H (2015). Public flue smoke treatment unit in residential building based on Internet of Things. In: Proceedings of the 2015 International conference on Applied Science and Engineering Innovation. Zhengzhou, China.
 

Han T, Park H, Jeong Y, et al. (2022). COVID-19 cluster linked to aerosol transmission of SARS-CoV-2 via floor drains. The Journal of Infectious Diseases, 225: 1554–1560.

 

Hwang SE, Chang JH, Oh B, Heo J (2021). Possible aerosol transmission of COVID-19 associated with an outbreak in an apartment in Seoul, South Korea, 2020. International Journal of Infectious Diseases, 104: 73–76.

 

Kang M, Wei J, Yuan J, et al. (2020). Probable evidence of fecal aerosol transmission of SARS-CoV-2 in a high-rise building. Annals of Internal Medicine, 173: 974–980.

 

Kotani H, Narasaki M, Sato R, et al. (2003). Environmental assessment of light well in high-rise apartment building. Building and Environment, 38: 283–289.

 
Li Y, Li Z, Mao S, et al. (2011). Numerical simulation reach of effect of external wind on flue gas movement pattern in high-rise building vertical shaft. In: Proceedings of 2011 International Conference on Multimedia Technology, Hangzhou, China.
 

Li M, Li F, Jing Y, et al. (2022a). Estimation of pollutant sources in multi-zone buildings through different deconvolution algorithms. Building Simulation, 15: 817–830.

 

Li S, Li Z, Dong Y, et al. (2022b). Temporal-spatial risk assessment of COVID-19 under the influence of urban spatial environmental parameters: The case of Shenyang city. Building Simulation, https://doi.org/10.1007/s12273-022-0918-8

 
Magyar Z (2022). Lecture 2: Natural ventilation. http://www.energiazero.org/inglese/Ventilation_lecture_MaZo.pdf. Accessed 1 Apr 2022.
 

McKinney KR, Gong YY, Lewis TG (2006). Environmental transmission of SARS at Amoy Gardens. Journal of Environmental Health, 68: 26–30.

 

Mijorski S, Cammelli S (2016). Stack effect in high-rise buildings: a review. International Journal of High-Rise Buildings, 5: 327–338.

 

Mizukoshi A, Nakama C, Okumura J, et al. (2021). Assessing the risk of COVID-19 from multiple pathways of exposure to SARS-CoV-2: Modeling in health-care settings and effectiveness of nonpharmaceutical interventions. Environment International, 147: 106338.

 

Morawska L, Tang JW, Bahnfleth W, et al. (2020). How can airborne transmission of COVID-19 indoors be minimised? Environment International, 142: 105832.

 

Shi K-W, Huang Y-H, Quon H, et al. (2021). Quantifying the risk of indoor drainage system in multi-unit apartment building as a transmission route of SARS-CoV-2. Science of The Total Environment, 762: 143056.

 

Sze To GN, Chao CYH (2010). Review and comparison between the Wells-Riley and dose-response approaches to risk assessment of infectious respiratory diseases. Indoor Air, 20: 2–16.

 

Wang Q, Li Y, Lung DC, et al. (2022a) Aerosol transmission of SARS-CoV-2 due to the chimney effect in two high-rise housing drainage stacks. Journal of Hazardous Materials, 421: 126799.

 

Wang Q, Lin Z, Niu J, et al. (2022b). Spread of SARS-CoV-2 aerosols via two connected drainage stacks in a high-rise housing outbreak of COVID-19. Journal of Hazardous Materials, 430: 128475.

 

Wang Q, Lung DC, Chan P-T, et al. (2022c). High attack rate in a Tong Lau house outbreak of COVID-19 with subdivided units in Hong Kong. Interface Focus, 12: 20210063.

 

Wei J, Yu Y, Wu Z (2015). The effect of thermal pressure on the central exhaust system of a 12-storey residential building. Journal of Nanjing Normal University (Engineering and Technology Edition), 2015(2): 25–29. (in Chinese)

 

Wong SC, Chen H, Lung DC, et al. (2021). To prevent SARS-CoV-2 transmission in designated quarantine hotel for travelers: Is the ventilation system a concern? Indoor Air, 31: 1295–1297.

 

Yip TL, Huang Y, Liang C (2021). Built environment and the metropolitan pandemic: Analysis of the COVID-19 spread in Hong Kong. Building and Environment, 188: 107471.

 

Zhang N, Jia W, Lei H, et al. (2021). Effects of human behavior changes during the coronavirus disease 2019 (COVID-19) pandemic on influenza spread in Hong Kong. Clinical Infectious Diseases, 73: e1142–e1150.

 

Zhao P, Chan P-T, Gao Y, et al. (2019). Physical factors that affect microbial transfer during surface touch. Building and Environment, 158: 28–38.

Building Simulation
Pages 701-711
Cite this article:
Zhao P. Analysis of COVID-19 clusters involving vertical transmission in residential buildings in Hong Kong. Building Simulation, 2023, 16(5): 701-711. https://doi.org/10.1007/s12273-022-0929-5

538

Views

8

Crossref

9

Web of Science

8

Scopus

0

CSCD

Altmetrics

Received: 03 May 2022
Revised: 19 July 2022
Accepted: 06 August 2022
Published: 31 August 2022
© Tsinghua University Press 2022
Return