Discover the SciOpen Platform and Achieve Your Research Goals with Ease.
Search articles, authors, keywords, DOl and etc.
Pressure monitoring of a transformer oil tank can grasp the pressure change process caused by gas production when severe internal defects occur and take timely measures to ensure the safe operation of the transformer. Existing pressure sensors generally use metal encapsulation or have an air cavity structure, threatening the transformer’s insulation if it is directly used inside the transformer. To this end, this paper proposes a method for developing a high-sensitivity, large-range, and metallization-free optical pressure sensing device with temperature compensation. Fiber grating is encapsulated by fluorosilicone rubber and supplemented by an epoxy resin shielding shell on the outside. At the same time, a double-grating vertical arrangement is adopted to improve pressure measurement sensitivity, further avoiding the influence of temperature rise caused by a defect of the transformer on the measurement result of the sensor. In addition, by optimizing the geometric structure of the internal sensitizing element, pre-stretching length of the fiber grating, gap distance, and other parameters, probe size can be reduced while ensuring the sensor’s performance. Results show the proposed method can meet the requirements of sensor fabrication with different sensitivities and ranges, and to a certain extent, both high sensitivity and extensive ranges can be taken into account. The sensitivity of the fabricated prototype is 15 pm/kPa, and the range is about 0.2 MPa. At the same time, the metal-free feature of the sensor makes it suitable for use in various oil-immersed power equipment. It records oil pressure changes caused by oil discharge breakdown, making it sensitive to small pressure changes in early failures.
R. Bansal, Power System Protection in Smart Grid Environment. Boca Raton: CRC Press, 2019.
S. Brodeur and J. B. Dastous, “Design and testing of an arc resistant power transformer tank,” IEEE Transactions on Power Delivery, vol. 35. no. 2, pp. 699–706, Apr. 2020.
C. Q. Pan, Z. H. Bie, G. F. Li, C. Wang and C. Yan, “Reliability evaluation of integrated energy system based on exergy,” CSEE Journal of Power and Energy Systems, pp. 1–9, 2022, doi: 10.17775/CSEEJPES.2020.03690.
Y. J. Zhang, J. Feng and S. Y. Wang, “A new method for transformer fault diagnosis by using improved clustering method,” CSEE Journal of Power and Energy Systems, pp. 1–11, 2022, doi: 10.17775/CSEEJPES.2021.03880.
N. Abi-Samra, J. Arteaga, B. Darovny, M. Foata, J. Herz, T. Lee, N. Van Nhi Nguyen, G. Perigaud, C. Swinderman, R. Thompson, G. Zhang, and P. D. Zhao, “Power transformer tank rupture and mitigation—a summary of current state of practice and knowledge by the task force of IEEE Power Transformer Subcommittee,” IEEE Transactions on Power Delivery, vol. 24. no. 4. pp. 1959–1967, Oct. 2009.
Q. M. Li, N. E. Ladislas, X. W. Huang, Q. S. Liu and Z. D. Wang, “Research advances of bubbles dynamics in power transformer,” CSEE Journal of Power and Energy Systems, pp. 1–17, 2021, doi: 10.17775/CSEEJPES.2020.04130.
P. Zhang, B. Qi, M. Y. Shao, C. R. Li, Z. H. Rong, J. X. Chen, and H. B. Wang, “Optimal data selection rule mining for transformer condition assessment,” IEEE Access, vol. 9, pp. 156962–156972, Nov. 2021.
P. Zubiate, J. M. Corres, C. R. Zamarreño, I. R. Matias, and F. J. Arregui, “Fabrication of optical fiber sensors for measuring ageing transformer oil in wavelength,” IEEE Sensors Journal, vol. 16, no. 12, pp. 4798–4802, Jun. 2016.
M. M. Yaacob, M. A. Alsaedi, J. R. Rashed, A. M. Dakhil, and S. F. Atyah, “Review on partial discharge detection techniques related to high voltage power equipment using different sensors,” Photonic Sensors, vol. 4, no. 4, pp. 325–337, Sep. 2014.
G. M. Ma, W. Q. Qin, Y. Du, H. Y. Zhou, Y. B. Li, C. Yan, and C. R. Li, “A centimeter resolution GIS insulator strain distribution measurement method based on OFDR,” IEEE Sensors Journal, vol. 19. no. 8, pp. 2962–2969, Apr. 2019.
Y. Q. Liu, Z. Y. Guo, Y. Zhang, K. S. Chiang, and X. Y. Dong, “Simultaneous pressure and temperature measurement with polymer-coated fibre Bragg grating,” Electronics Letters, vol. 36, no. 6, pp. 564–566, Mar. 2000.
Y. Zhang, Z. G. Liu, Z. Y. Guo, S. Z. Yuan, D. J. Feng, X. Y. Dong, and C. D. Yao, “A high-sensitivity fiber grating pressure sensor and its pressure sensing characteristics,” Acta Optica Sinica, vol. 22. no. 1. pp. 89–91, Jan. 2002.
X. Wang, J. F. Jiang, S. Wang, K. Liu, and T. G. Liu, “All-silicon dual-cavity fiber-optic pressure sensor with ultralow pressure-temperature cross-sensitivity and wide working temperature range,” Photonics Research, vol. 9, no. 4, pp. 521–529, Apr. 2021.
C. A. R. Díaz, A. G. Leal-Junior, P. S. B. André, P. F. Da Costa Antunes, M. J. Pontes, A. Frizera-Neto, and M. R. N. Ribeiro, “Liquid level measurement based on FBG-embedded diaphragms with temperature compensation,” IEEE Sensors Journal, vol. 18, no. 1, pp. 193–200, Jan. 2018.
A. G. Leal-Junior, A. Theodosiou, C. Marques, M. J. Pontes, K. Kalli, and A. Frizera, “Compensation method for temperature cross-sensitivity in transverse force applications with FBG sensors in POFs,” Journal of Lightwave Technology, vol. 36, no. 17, pp. 3660–3665, Sep. 2018.
H. Liang, P. G. Jia, J. Liu, G. C. Fang, Z. Li, Y. P. Hong, T. Liang, and J. J. Xiong, “Diaphragm-free fiber-optic Fabry-Perot interferometric gas pressure sensor for high temperature application,” Sensors, vol. 18, no. 4, pp. 1011, Mar. 2018.
L. Xiong, G. Z. Jiang, Y. X. Guo, Y. Kuang, and H. H. Liu, “Investigation of the temperature compensation of FBGs encapsulated with different methods and subjected to different temperature change rates,” Journal of Lightwave Technology, vol. 37, no. 3, pp. 917–926, Feb. 2019.
F. F. Ren, W. F. Zhang, Y. W. Li, Y. D. Lan, Y. K. Xie, and W. Dai, “The temperature compensation of FBG sensor for monitoring the stress on hole-edge,” IEEE Photonics Journal, vol. 10, no. 4. pp. 7104309, Aug. 2018.
K. T. V. Grattan and B. T. Meggitt, Optical Fiber Sensor Technology: Fundamentals. New York: Springer, 1998.
273
Views
12
Downloads
0
Crossref
0
Web of Science
1
Scopus
0
CSCD
Altmetrics
This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).