AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (13.5 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Open Access

Numerical Study of the Effect of Elastomer and Cement of Stress Absorbers on the Reduction of Stresses in Tibia and Tibial Bone Analysed by Finite Element Method

Abdelkader Mestar1( )Samir Zahaf2( )Nourddine Zina3Ahmed Boutaous1
Département technologie des matériaux, université des sciences et de la technologie d'Oran Mohamed Boudiaf, USTO-MB, BP 1505, EL M'naouer, 31000 Oran Algérie
Département de génie mécanique, université des sciences et de la technologie d'Oran Mohamed Boudiaf, USTO-MB, BP 1505, EL M'naouer, 31000 Oran Algérie
Département de génie mécanique, Ecole nationale polytechnique d'Oran BP 1523 M'naour, Oran 31000 Algeria
Show Author Information

Abstract

Metal alloys have been the materials of choice since the start of orthopaedic surgery. Orthopedic materials must fulfill the mechanical, biological and physical necessities of their proposed utilization. Knee joint is the most complex joint in human body, which gets the discriminating loads in different moving conditions. Accordingly, the material utilized for knee implant is assumed the exceptionally essential part for long survival of knee prosthesis. The materials that are utilized as biomaterials incorporate polymers, metals, ceramics and composites. Out of those materials, cobalt-chromium alloys, titanium alloys, stainless steel and ultra high molecular weight polyethylene are the most usually utilized biomaterials for knee implants. The objective of this paper is to prepare three models of prosthesis knee joint from available literature and study on the distribution of von Mises stresses and strains in different components of knee prosthesis. It is known that the total displacement between the intact model and the artificial model of knee, 3D modeling software Solidworks 2016 is used for 3D modeling of knee prosthesis, and that finite element analysis software ANSYS 16.2 was used for numerical estimation of von Mises stresses and strains. We found in this study that the maximum von Mises stresses and strains at the level of the tibial and tibial bone decreased, that is to say, the cement and the elastomer played a very important role in the absorption of the stresses and their minimization. On the other hand, the four knee prostheses (model Ⅰ (Ti6Al4V), model Ⅱ (CoCrMo), model Ⅲ (316L SS), model Ⅳ (ZrO2)) implanted by elastomer contributed significantly to the reduction of stresses in the patella bone compared to the intact model. In general, both models of the knee prosthesis and those reinforced by a stress reduction system (cement or elastomer) gave a lower stress level in the tibia and tibial bone of a normal person compared to a healthy model. The results obtained provide a theoretical basis for choosing an appropriate surgical model.

References

[1]

B.B. Seedhom, E.B. Longton, D. Dowson, et al., Biomechanics background in the design of total replacement knee prostheses. Acta Orthopaedica Belgica, 1973, 39: 164-180.

[2]

V.C. Mow, Role of lubrication in biomechanical joints. J. Lub. Tech, 1969, 91: 320-326.

[3]

J.M. Penrose, G.M. Holt, M. Beaugonin, et al., Development of an accurate three-dimensional finite element knee model. Comput Methods Biomech Biomed Engin, 2002, 5(4): 291-300.

[4]
ESI Group, VPS performance solution 2013: Solver reference manual. ESI Group, 2013.
[5]

T.L. Donahue, M.L. Hull, M.M. Rashid, et al., A finite element model of the human knee joint for the study of tibio-femoral contact. Journal of Biomechanical Engineering, 2002, 124(3): 273-280.

[6]

D.E.T. Shepherd, B.B. Seedhom, The 'instantaneous' compressive modulus of human articular cartilage in joints of the lower limb. Rheumatology, 1999, 38(2): 124-132.

[7]
R. Whipple, Advances in bioengineering. ASME, 1984.
[8]

M. Tissakht, A.M. Ahmed, Tensile stress-strain characteristics of the human meniscal material. Journal of Biomechanics, 1995, 4: 411-422.

[9]

D.L. Skaggs, W.H. Warden, and V.C. Mow, Radial tie fibers influence the tensile properties of the bovine medial meniscus. Journal of Orthopaedic Research, 1994, 12(2): 176-185.

[10]

D.C. Fithian, M.A. Kelly, and V.C. Mow, Material properties and structure-function relationships in the menisci. Clinical Orthopaedics and Related Research, 1990, 252: 19-31.

[11]

R.M. Aspden, A model for the function and failure of the meniscus. Engineering in Medicine, 1985, 14(3): 119-122.

[12]

A. Sabatini, T. Goswami, Hip implants Ⅶ: Finite element analysis and optimization of cross-sections. Materials and Design, 2008, 29(7): 1438-1446.

[13]

G.Z. Wang, F.Z. Xuan, Effects of triaxial stress on martensite transformation, stress-strain and failure behavior in front of crack tips in shape memory alloy NiTi. Materials Science and Engineering A, 2010, 527(6): 1529-1536.

[14]

C. Kleinstreuer, Z. Li, Computational mechanics of Nitinol stent grafts. Journal of Biomechanics, 2008, 41(11): 2370-2378.

[15]

A.G. Au, D. Palathinkal, A.B. Liggins, et al., A NURBS-based technique for subject-specific construction of knee bone geometry. Computer Methods and Programs in Biomedicine, 2008, 92: 20-34.

[16]
AZoMTM. com, Accelerated ageing and characterisation of UHMWPE used in orthopaedic implants. Retrieved 28/02/2014, < http://www.azom.com/properties.aspx?ArticleID=909 > .
[17]

S. Hosseini, Biomedical engineering-technical applications in fatigue of Ti-6Al-4V. INTECH Open Access Publisher, 2012, 3: 75-91.

[18]
American Society for Testing and Materials. 1992, F75-87: 42, F90-87: 47, and F562-84: 150.
[19]

J. Geringer, F. Atmani, and B. Forest, Friction–corrosion of AISI 316L/bone cement and AISI 316, L/PMMA contacts, Ionic strength effect on tribological behaviour. Wear, 2009, 267(5-8): 763-769.

[20]

Y. Guo, X. Zhang, and W. Chen, Three-dimensional finite element simulation of total knee joint in gait cycle. Acta Mechanica Solida Sinica, 2009, 22(4): 347-351.

[21]

T. Sawatari, H. Tsumura, K. Iesaka, et al., Three-dimensional finite element analysis of unicompartmental knee arthroplasty- The influence of tibial component inclination. J Orthop Res, 2005, 23: 549-554.

[22]

G.D. Zhu, W.S. Guo, Q.D. Zhang, et al., Finite element analysis of mobile-bearing unicompartmental knee arthroplasty: The influence of tibial component coronal alignment. Chin Med J, 2015, 128: 2873-2878.

[23]

K. Iesaka, H. Tsumura, H. Sonoda, et al., The effects of tibial component inclination on bone stress after unicompartmental knee arthroplasty. J Biomech, 2002, 35: 969-974.

[24]

D.J. Simpson, A.J. Price, A. Gulati, et al., Elevated proximal tibial strains following unicompartmental knee replacement - A possible cause of pain. Med Eng Phys, 2009, 31: 752-757.

[25]

O.R. Kwon, K.T. Kang, J. Son, et al., Biomechanical comparison of fixed- and mobile-bearing for unicomparmental knee arthroplasty using finite element analysis. J Orthop Res, 2014, 32(2): 338-345.

[26]

E. Peña, B. Calvo, M.A. Martínez, et al., A three-dimensional finite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint. Biomech J, 2006, 39: 1686-1701.

[27]

A.R. Hopkins, A.M. New, F. Rodriguez-y-Baena, et al., Finite element analysis of unicompartmental knee arthroplasty, Med Eng Phys, 32 (2010) 14-21.

[28]

H.R. Bao, D. Zhu, H. Gong, et al., The effect of complete radial lateral meniscus posterior root tear on the knee contact mechanics: A finite element analysis. J Orthop Sci, 2013, 18: 256-263.

Nano Biomedicine and Engineering
Pages 56-78
Cite this article:
Mestar A, Zahaf S, Zina N, et al. Numerical Study of the Effect of Elastomer and Cement of Stress Absorbers on the Reduction of Stresses in Tibia and Tibial Bone Analysed by Finite Element Method. Nano Biomedicine and Engineering, 2018, 10(1): 56-78. https://doi.org/10.5101/nbe.v10i1.p56-78

726

Views

46

Downloads

2

Crossref

7

Scopus

Altmetrics

Received: 16 February 2018
Accepted: 27 March 2018
Published: 29 March 2018
© Abdelkader Mestar, Samir Zahaf, Nourddine Zina, and Ahmed Boutaous.

This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Return