AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (4.3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Open Access

Design of Ultrasensitive Electrochemical Aptasensor for Earlier Detection of Hepatitis B Virus

Dheyaa Hussein Mohsin1,2( )Muthana Saleh Mashkour3Fataneh Fatemi4Emad Salaam Abood5
Chemistry Department, Collage of Science, University of Kufa, Iraq
General directorate for education in Najaf, ministry of education, Iraq
Chemistry Department, Collage of Science, University of Kufa, Iraq
Shahid Beheshti University G.C, Protein Research Center, Tehran, Iran
Medical physics, Hilla University collage, Babylon, Iraq
Show Author Information

Abstract

In consideration of the imperious need for developing a simple, ultra-sensitive and selective method to detect Hepatitis B virus (HBV), an label free aptasensor was constructed by the modification of a chemically inert glassy carbon electrode (GCE) by dint of a gold nanoparticle immobilized reduced graphene oxide. The ultrasensitive detection was attained using a specific ssDNA (thiolated aptamer at the 5′ end) as a recognition element. The aptamer was fastened onto GCE/rGO/Au surface via the Au-S bond for determining the impedance of charge mobility by means of [Fe(CN)6]3-/4- as a redox gauge. The function of aptasensor based on the specific interaction between the aptamer and specific surface antigen HBsAg induced [HBsAg-aptamer] complex formation which impeded electron movability between a [Fe(CN)6]3-/4- redox probe solution and sensing interface. HBsAg-binding aptamer events can be easily monitored by the signal switch through cyclic voltammetry technique (CV), square wave voltammetry (SWV), and electrochemical impedance spectroscopy (EIS) measurements. Under the optimized conditions, the aptasensor can detect HBsAg in the 0.25 fg/mL to 1.5 fg/mL concentration range and limit of detection of 0.018, 0.0016 and 0.001 fg/mL for CV, SWV and EIS respectively. The recovery of 88-109.6% was obtained. Moreover, the selectivity of the aptasensor was tested using other biological interfering substances. This developed aptasensor provided one of the lowest limits of detection for HBsAg recently reported in the literature, satisfying stability and good reproducibility, consequently could be applied for revealing HBsAg in real samples.

References

[1]

J. Torresi, B.M. Tran, D. Christiansen, et al., HBV-related hepatocarcinogenesis: the role of signalling pathways and innovative ex vivo research models. BMC Cancer, 2019, 19(1): 707.

[2]

D. Lavanchy, Hepatitis B virus epidemiology, disease burden, treatment, arid current and emerging prevention and control measures. Viral Hepat, 2004, 11(2): 97-107.

[3]

U. Yildiz, F. HakanInci, S. Wang, et al., Recent advances in micro/nanotechnologies for global control of hepatitis B infection. Biotechnol. Adv. [Internet], 2015, 33(1): 178-190.

[4]

E. Orito, T. Ichida, H. Sakugawa, et al., Geographic distribution of hepatitis B virus (HBV) genotype in patients with chronic HBV infection in Japan. Hepatology, 2001, 34(3): 590-594.

[5]

T. Mitchell, G. Armstrong, and D. Hu, The increasing burden of imported chronic hepatitis B - United States, 1974-2008. PLoS One, 2011, 6(12): 6-11.

[6]

T. Araya Mezgebo, S. Niguse, A. Gebrekidan Kahsay, et al., Hepatitis B virus infection and associated risk factors among pregnant women attending antenatal care in health facilities of Tigray. Northern Ethiopia. J. Med. Virol., 2018, 90(3): 503-509.

[7]

J. MacLachlan, S. Locarnini, and B. Cowie, Estimating the global prevalence of hepatitis B. Lancet[Internet], 2015, 386(10003): 1515-1517.

[8]

P. Karayiannis. Hepatitis B virus: virology, molecular biology, life cycle and intrahepatic spread. Hepatol, 2017.

[9]

C. Trépo, H. Chan, and A. Lok. Hepatitis B virus infection. Lancet, 2014, 384(9959): 2053-2063.

[10]

C. Bosetti, F. Turati, and C. La Vecchia, Hepatocellular carcinoma epidemiology. Best Pract. Res. Clin. Gastroenterol, 2014, 28(5): 753-770.

[11]

Z. Li, X. Hou, and G. Cao, Is mother-to-infant transmission the most important factor for persistent HBV infection? Emerg. Microbes Infect, 2015, 4(5).

[12]

S. Molla, A. Munshea, and E. Nibret, Seroprevalence of hepatitis B surface antigen and anti HCV antibody and its associated risk factors among pregnant women attending maternity ward of Felege Hiwot Referral Hospital, northwest Ethiopia: A cross-sectional study Hepatitis viruses. Virol. J., 2015, 12(1): 1-9.

[13]

C. Seeger, W. Mason, Molecular biology of hepatitis B virus infection. Virology, 2015, 479-480: 672-686.

[14]

S. Noppornpanth, N. Sathirapongsasuti, V. Chongsrisawat, et al., Detection of HbsAg and HBV DNA in serum and saliva of HBV carriers. Southeast Asian J. Trop. Med. Public Health, 2000, 31(2): 419-421.

[15]

C. Shepard, E. Simard, L. Finelli, et al., Hepatitis B virus infection: Epidemiology and vaccination. Epidemiol. Rev., 2006, 28(1): 112-125.

[16]

H. Chan, A. Thompson, M. Martinot-Peignoux, et al., Hepatitis B surface antigen quantification: Why and how to use it in 2011 - A core group report. J. Hepatol., 2011, 55(5): 1121-1131.

[17]

Z. Xi, Q. Gong, C. Wang, et al., Highly sensitive chemiluminescent aptasensor for detecting HBV infection based on rapid magnetic separation and double-functionalized gold nanoparticles. Sci. Rep., 2018, 8(1): 1-7.

[18]

P. Zhang, H. Lu, J. Chen, et al., Simple and sensitive detection of HBsAg by using a quantum dots nanobeads based dot-blot immunoassay. Theranostics, 2014, 4(3): 307-315.

[19]

E. Alipour, H. Ghourchian, and S. Boutorabi, Gold nanoparticle based capacitive immunosensor for detection of hepatitis B surface antigen. Anal. Methods, 2013, 5(17): 4448-4453.

[20]

C. Yao, W. Fu, Biosensors for hepatitis B virus detection. World J. Gastroenterol, 2014, 20(35): 12485-12492.

[21]

Y. Wu, W. Guo, W. Peng, et al., Enhanced fluorescence ELISA based on HAT triggering fluorescence "turn-on" with enzyme-antibody dual labeled AuNP probes for ultrasensitive detection of AFP and HBsAg. ACS Appl. Mater. Interfaces, 2017, 9(11): 9369-9377.

[22]

R. Akter, C. Rhee, and M. Rahman, A highly sensitive quartz crystal microbalance immunosensor based on magnetic bead-supported bienzymes catalyzed mass enhancement strategy. Biosens. Bioelectron., 2015, 66: 539-546.

[23]

M. Wiederoder, I. Misri, and D. DeVoe. Impedimetric immunosensing in a porous volumetric microfluidic detector. Sensors Actuators, B Chem., 2016, 234: 493-497.

[24]

M. Ehsani, M. Chaichi, and S. Nezammeddin Hosseini, Comparison of CuO nanoparticle and CuO/MWCNT nanocomposite for amplification of chemiluminescence immunoassay for detection of the hepatitis B surface antigen in biological samples. Sensors Actuators, B Chem., 2017, 247: 319-328.

[25]

J. Kim, S. Oh, S. Shukla, et al., Heteroassembled gold nanoparticles with sandwich-immunoassay LSPR chip format for rapid and sensitive detection of hepatitis B virus surface antigen (HBsAg). Biosens. Bioelectron., 2018, 107: 118-122.

[26]

T. Riedel, F. Surman, S. Hageneder, et al., Hepatitis B plasmonic biosensor for the analysis of clinical serum samples. Biosens. Bioelectron., 2016, 85: 272-279.

[27]

P. Tighe, R. Ryder, I. Todd, et al., ELISA in the multiplex era: Potentials and pitfalls. Proteomics - Clin. Appl., 2015, 9(3-4): 422.

[28]

N. Xia, X. Wang, and B. Zhou, Electrochemical detection of amyloid-β oligomers based on the signal amplification of a network of silver nanoparticles. ACS Appl. Mater. Interfaces, 2016, 8(30): 19303-19311.

[29]

B. Deng, Y. Lin, C. Wang, et al., Aptamer binding assays for proteins: The thrombin example - A review. Anal. Chim. Acta., 2014, 837: 1-15.

[30]

M. Saberian-Borujeni, M. Johari-Ahar, H. Hamzeiy, et al., Nanoscaled aptasensors for multi-analyte sensing. BioImpacts, 2014, 4(4): 205-215.

[31]

H. Sun, Y. Zu. A Highlight of recent advances in aptamer technology and its application. Molecules, 2015, 20(7): 11959-11980.

[32]

K. Ghanbari, M. Roushani, and A. Azadbakht, Ultra-sensitive aptasensor based on a GQD nanocomposite for detection of hepatitis C virus core antigen. Anal. Biochem., 2017, 534: 64-69.

[33]

R. Torabi, K. Bagherzadeh, H. Ghourchian, et al., An investigation on the interaction modes of a single-strand DNA aptamer and RBP4 protein: A molecular dynamic simulations approach. Org. Biomol. Chem., 2016, 14(34): 8141-8153.

[34]

P. Hong, W. Li, and J. Li, Applications of aptasensors in clinical diagnostics. Sensors, 2012, 12(2): 1181-1193.

[35]

P. Bollella, G. Fusco, C. Tortolini, et al., Beyond graphene: Electrochemical sensors and biosensors for biomarkers detection. Biosens Bioelectron., 2017, 89: 152-166.

[36]

G. Zhang, Z. Liu, L. Fan, Electrochemical prostate specific antigen aptasensor based on hemin functionalized graphene-conjugated palladium nanocomposites. Microchim. Acta., 2018, 185(3): 1-8.

[37]

I. Dinshaw, S. Muniandy, and S. Teh, Development of an aptasensor using reduced graphene oxide chitosan complex to detect Salmonella. J. Electroanal. Chem., 2017, 806: 88-96.

[38]

W. Argoubi, A. Sánchez, C. Parrado, et al., Label-free electrochemical aptasensing platform based on mesoporous silica thin film for the detection of prostate specific antigen. Sensors Actuators, B Chem., 2018, 255: 309-315.

[39]

G. Rozenblum, I. Pollitzer, and M. Radrizzani, Challenges in electrochemical aptasensors and current sensing architectures using flat gold surfaces. Chemosensors, 2019, 7(57).

[40]

Y. Ye, J. Xie, X. Cao, et al., A label-free electrochemical DNA biosensor based on thionine functionalized reduced graphene oxide. Carbon N. Y., 2018, 129: 730-737.

[41]

Z. Matharu, P. Daggumati, L. Wang, et al., Nanoporous-gold-based electrode morphology libraries for investigating structure-property relationships in nucleic acid based electrochemical biosensors. ACS Appl. Mater. Interfaces, 2017, 9(15): 12959-12966.

[42]

M. Chen, C. Hou, and D. Huo, A sensitive electrochemical DNA biosensor based on three-dimensional nitrogen-doped graphene and Fe3O4 nanoparticles. Sensors Actuators, B Chem., 2017, 239: 421-429.

[43]

S. Vashist, J. Luong, Recent advances in electrochemical biosensing schemes using graphene and graphene-based nanocomposites. Carbon N. Y., 2015, 84(1): 519-550.

[44]

I. Khalil, N. Julkapli, W. Yehye, et al., Graphene-gold nanoparticles hybrid-synthesis, functionalization, and application in a electrochemical and surface-enhanced Raman scattering. Biosensor, 2016.

[45]

K. Turcheniuk, R. Boukherroub, and S. Szunerits, Gold-graphene nanocomposites for sensing and biomedical applications. J. Mater. Chem. B., 2015, 3(21): 4301-4324.

[46]

M. Govindhan, M. Amiri, and A. Chen, Au nanoparticle/graphene nanocomposite as a platform for the sensitive detection of NADH in human urine. Biosens. Bioelectron., 2015, 66: 474-480.

[47]

B. Crulhas, C. Basso, J. Parra, et al., Pedrosa VA. Reduced. J. Sensors. 2019.

[48]

Z. Xi, R. Huang, Z. Li, et al., Selection of HBsAg-specific DNA aptamers based on carboxylated magnetic nanoparticles and their application in the rapid and simple detection of hepatitis b virus infection. ACS Appl. Mater. Interfaces, 2015, 7(21): 11215-11223.

[49]

J. Guerrero-Contreras, Graphene oxide powders with different oxidation degree, prepared by synthesis variations of the Hummers method. Mater. Chem. Phys., 2015.

[50]

S. Willium. Preparation of graphitic oxide. ACS. Am. Chem., 1957, 208(1937): 1937.

[51]

N. Cao, Y. Zhang, Study of reduced graphene oxide preparation by hummers' method and related characterization. J. Nanomater., 2015.

[52]

M. Poorali, M. Bagheri-Mohagheghi, Comparison of chemical and physical reduction methods to prepare layered graphene by graphene oxide: optimization of the structural properties and tuning of energy band gap. J. Mater. Sci. Mater. Electron., 2016, 27(1): 260-271.

[53]

Q. Zhang, D. Zhang, Y. Lu, et al., Label-free amino acid detection based on nanocomposites of graphene oxide hybridized with gold nanoparticles. Biosens. Bioelectron., 2016, 77: 963-970.

[54]

S. Georgitsopoulou, O. Petrai, and V. Georgakilas, Highly conductive functionalized reduced graphene oxide. Surfaces and Interfaces, 2019, 16: 152-156.

[55]

P. Assari, A. Rafati, A. Feizollahi, et al., An electrochemical immunosensor for the prostate specific antigen based on the use of reduced graphene oxide decorated with gold nanoparticles. Microchim. Acta., 2019, 186(7).

[56]

L. Guardia, J. Paredes, and P. Solı, Vitamin C is an ideal substitute for hydrazine in the reduction of graphene. Oxide Suspensions, 2010: 6426-6432.

[57]

W. Ithin, comparison. Gold nanoparticles-reduced graphene oxide based electrochemical immunosensor for the cardiac biomarker myoglobin. Microchim. Acta., 2016, 183(5): 1729-1738.

[58]

A. Matloob, D. El-hafiz, L. Saad, et al., Green Synthesis of Graphite Oxide as Metal Free Catalyst for Petrochemicals. Production, 2016, 3: 131-142.

[59]

S. Gurunathan, J. Han, E. Kim, et al., Reduction of graphene oxide by resveratrol: A novel and simple biological method for the synthesis of an effective anticancer nanotherapeutic molecule. Int. J. Nanomedicine, 2015, 10: 2951-2969.

[60]

H. Jeong, M. Jin, and K. So. Tailoring the characteristics of graphite oxides by different oxidation times. J. Phys. D. Appl. Phys., 2009, 42(6).

[61]

S. Otari., M. Kumar, M. Anwar, et al., Rapid synthesis and decoration of reduced graphene oxide with gold nanoparticles by thermostable peptides for memory device and photothermal applications. Sci. Rep., 2017, 7(1).

[62]

B. Özcan, M. Sezgintürk. B, GraÖzcan, et al., Graphene oxide based electrochemical label free immunosensor for rapid and highly sensitive determination of tumor marker HSP70. Talanta, 2016, 160: 367-374.

[63]

S. Baghbaderani, A. Noorbakhsh, Novel chitosan-Nafion composite for fabrication of highly sensitive impedimetric and colorimetric As(Ⅲ) aptasensor. Biosens. Bioelectron., 2019, 131(Iii): 1-8.

[64]

L. Feng, Y. Chen, A graphene functionalized electrochemical aptasensor for selective label-free detection of cancer cells. Biomaterials, 2011, 32(11): 2930-2937.

[65]

H. Lv, Y. Li, X. Zhang, et al., The label-free immunosensor based on rhodium@palladium nanodendrites/sulfo group functionalized multi-walled carbon nano tubes for the sensitive analysis of carcino embryonic antigendenaturization. Anal. Chim. Acta, 2018, 1007: 61-70.

[66]

T. Tyner, J. Francis. Potassium ferricyanide. ACS Reag. Chem., 2017, 77(58).

[67]

A. Shrivastava, V. Gupta, Methods for the determination of limit of detection and limit of quantitation of the analytical methods. Chronicles Young Sci., 2011, 2(1): 21.

[68]

D. Cabral, E. Lima, and P. Moura, A label-free electrochemical immunosensor for hepatitis B based on hyaluronic acid-carbon nanotube hybrid film. Talanta, 2016, 148: 209-215.

[69]

G. Shen, Y. Shen, X. Zhang, et al., Electrochemistry. 2016: 3-6.

[70]

Y. Choi, G. Lee, H. Ko, et al., Development of SPR biosensor for the detection of human hepatitis B virus using plasma-treated parylene-N film. Biosens. Bioelectron., 2014, 56: 286-294.

[71]

H. Tsai, J. Chan, Y. Li. Determination of hepatitis B surface antigen using magnetic immunoassays in a thin channel. Biosens. Bioelectron., 2010, 25(12): 2701-2705.

[72]

S. Kim. ELISA for quantitative determination of hepatitis b virus surface antigen. Immune Netw, 2017, 17(6): 451-459.

[73]

Y Li, L Tian, L. Liu, et al., An ultrasensitive sandwich-type electrochemical immunosensor based on δ-MnO2 and palladium nanoparticles covered natural halloysite nanotubes for the detection of hepatitis B surface antigen. New J. Chem., 2016, 40(1): 558-563.

[74]

C. Akkapinyo, P. Khownarumit, D. Waraho-Zhmayev, et al., Development of a multiplex immunochromatographic strip test and ultrasensitive electrochemical immunosensor for hepatitis B virus screening. Anal. Chim. Acta, 2020, 1095: 162-171.

Nano Biomedicine and Engineering
Pages 150-164
Cite this article:
Hussein Mohsin D, Saleh Mashkour M, Fatemi F, et al. Design of Ultrasensitive Electrochemical Aptasensor for Earlier Detection of Hepatitis B Virus. Nano Biomedicine and Engineering, 2021, 13(2): 150-164. https://doi.org/10.5101/nbe.v13i2.p150-164

643

Views

42

Downloads

4

Crossref

4

Scopus

Altmetrics

Received: 17 September 2020
Accepted: 28 January 2021
Published: 29 April 2021
© Dheyaa Hussein Mohsin, Muthana Saleh Mashkour, Fataneh Fatemi, and Emad Salaam Abood.

This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Return