Discover the SciOpen Platform and Achieve Your Research Goals with Ease.
Search articles, authors, keywords, DOl and etc.
Synthetic vascular grafts suitable for small-diameter arteries (<6 mm) are in great need. However, there are still no commercially available small-diameter vascular grafts (SDVGs) in clinical practice due to thrombosis and stenosis after in vivo implantation. When designing SDVGs, many studies emphasized reendothelization but ignored the importance of reconstruction of the smooth muscle layer (SML). To facilitate rapid SML regeneration, a high-resolution 3D printing method was used to create a novel bilayer SDVG with structures and mechanical properties mimicking natural arteries. Bioinspired by the collagen alignment of SML, the inner layer of the grafts had larger pore sizes and high porosity to accelerate the infiltration of cells and their circumferential alignment, which could facilitate SML reconstruction for compliance restoration and spontaneous endothelialization. The outer layer was designed to induce fibroblast recruitment by low porosity and minor pore size and provide SDVG with sufficient mechanical strength. One month after implantation, the arteries regenerated by 3D-printed grafts exhibited better pulsatility than electrospun grafts, with a compliance (8.9%) approaching that of natural arteries (11.36%) and significantly higher than that of electrospun ones (1.9%). The 3D-printed vascular demonstrated a three-layer structure more closely resembling natural arteries while electrospun grafts showed incomplete endothelium and immature SML. Our study shows the importance of SML reconstruction during vascular graft regeneration and provides an effective strategy to reconstruct blood vessels through 3D-printed structures rapidly.
Edelman E R 1999 Vascular tissue engineering Circ. Res. 85 1115–7
Goldman S, McCarren M, Sethi G K, Holman W, Bakaeen F G, Wagner T H, Wang Y J, Shih M C, Edson R and The CSP #474 Investigators 2022 Long-term mortality follow-up of radial artery versus saphenous vein in coronary artery bypass grafting: a multicenter, randomized trial Circulation 146 1323–5
Gaudino M et al 2022 Radial artery versus saphenous vein versus right internal thoracic artery for coronary artery bypass grafting Eur. J. Cardiothorac. Surg. 62 ezac345
Maestri F, Formica F, Gallingani A, Gripshi F and Nicolini F 2022 Radial artery versus saphenous vein as third conduit in coronary artery bypass graft surgery for multivessel coronary artery disease: a ten-year literature review Acta Biomed. 93 e2022049
Nezic D 2022 Radial artery versus saphenous vein graft for coronary artery bypass grafting-long-term outcomes Eur. J. Cardiothorac. Surg. 62 ezac371
Klinkert P, Post P N, Breslau P J and van Bockel J H 2004 Saphenous vein versus PTFE for above-knee femoropopliteal bypass. A review of the literature Eur. J. Vascular Endovasc. Surg. 27 357–62
Lim J, Won J Y, Ahn C B, Kim J, Kim H J and Jung J S 2021 Comparison of hemodynamic energy between expanded polytetrafluoroethylene and dacron artificial vessels J. Chest Surg. 54 81–87
Takagi H, Goto S N, Matsui M, Manabe H and Umemoto T 2010 A contemporary meta-analysis of dacron versus polytetrafluoroethylene grafts for femoropopliteal bypass grafting J. Vascular Surg. 52 232–6
Tanaka T, Abe Y, Cheng C J, Tanaka R, Naito A and Asakura T 2021 Development of small-diameter elastin-silk fibroin vascular grafts Front. Bioeng. Biotechnol. 8 622220
Tanaka T, Tanaka R, Ogawa Y, Takagi Y and Asakura T 2020 Development of small-diameter polyester vascular grafts coated with silk fibroin sponge Organogenesis 16 1–13
Abbott W M, Callow A, Moore W, Rutherford R, Veith F and Weinberg S 1993 Evaluation and performance standards for arterial prostheses J. Vascular Surg. 17 746–56
Wagenseil J E and Mecham R P 2009 Vascular extracellular matrix and arterial mechanics Physiol. Rev. 89 957–89
Zia A W, Liu R and Wu X B 2022 Structural design and mechanical performance of composite vascular grafts Biodes. Manuf. 5 757–85
Halper J 2018 Basic components of vascular connective tissue and extracellular matrix Adv. Pharmacol. 81 95–127
Miyagawa K et al 2019 Smooth muscle contact drives endothelial regeneration by BMPR2-Notch1–mediated metabolic and epigenetic changes Circ. Res. 124 211–24
Yurdagul A 2022 Crosstalk between macrophages and vascular smooth muscle cells in atherosclerotic plaque stability Arterioscler. Thromb. Vascular Biol. 42 372–80
Wen M L, Zhi D K, Wang L N, Cui C, Huang Z Q, Zhao Y H, Wang K, Kong D L and Yuan X Y 2020 Local delivery of dual micrornas in trilayered electrospun grafts for vascular regeneration ACS Appl. Mater. Interfaces 12 6863–75
Ju Y M, Ahn H, Arenas-Herrera J, Kim C, Abolbashari M, Atala A, Yoo J J and Lee S J 2017 Electrospun vascular scaffold for cellularized small diameter blood vessels: a preclinical large animal study Acta Biomater. 59 58–67
Lee S J, Liu J, Oh S H, Soker S, Atala A and Yoo J J 2008 Development of a composite vascular scaffolding system that withstands physiological vascular conditions Biomaterials 29 2891–8
Pan Y W et al 2017 Small-diameter hybrid vascular grafts composed of polycaprolactone and polydioxanone fibers Sci. Rep. 7 3615
Zhu M F et al 2018 Biodegradable and elastomeric vascular grafts enable vascular remodeling Biomaterials 183 306–18
Pektok E, Nottelet B, Tille J C, Gurny R, Kalangos A, Moeller M and Walpoth B H 2008 Degradation and healing characteristics of small-diameter poly(ϵ-caprolactone) vascular grafts in the rat systemic arterial circulation Circulation 118 2563–70
Wang Z H et al 2014 The effect of thick fibers and large pores of electrospun poly(ε-caprolactone) vascular grafts on macrophage polarization and arterial regeneration Biomaterials 35 5700–10
de Valence S, Tille J C, Mugnai D, Mrowczynski W, Gurny R, Möller M and Walpoth B H 2012 Long term performance of polycaprolactone vascular grafts in a rat abdominal aorta replacement model Biomaterials 33 38–47
Patterson J, Martino M M and Hubbell J A 2010 Biomimetic materials in tissue engineering Mater. Today 13 14–22
Cunnane E M, Davis N F, Cunnane C V, Lorentz K L, Ryan A J, Hess J, Weinbaum J S, Walsh M T, O’Brien F J and Vorp D A 2021 Mechanical, compositional and morphological characterisation of the human male urethra for the development of a biomimetic tissue engineered urethral scaffold Biomaterials 269 120651
Timmins L H, Wu Q F, Yeh A T, Moore J E and Greenwald S E 2010 Structural inhomogeneity and fiber orientation in the inner arterial media Am. J. Physiol. Heart. Circ. Physiol. 298 H1537–45
Schriefl A J, Zeindlinger G, Pierce D M, Regitnig P and Holzapfel G A 2012 Determination of the layer-specific distributed collagen fibre orientations in human thoracic and abdominal aortas and common iliac arteries J. R. Soc. Interface 9 1275–86
Li Y H, Huang G Y, Zhang X H, Wang L, Du Y N, Lu T J and Xu F 2014 Engineering cell alignment in vitro Biotechnol. Adv. 32 347–65
Saidy N T, Shabab T, Bas O, Rojas-González D M, Menne M, Henry T, Hutmacher D W, Mela P and De-Juan-Pardo E M 2020 Melt electrowriting of complex 3D anatomically relevant scaffolds Front. Bioeng. Biotechnol. 8 793
Chan-Park M B, Shen J Y, Cao Y, Xiong Y, Liu Y X, Rayatpisheh S, Kang G C W and Greisler H P 2009 Biomimetic control of vascular smooth muscle cell morphology and phenotype for functional tissue-engineered small-diameter blood vessels J. Biomed. Mater. Res. A 88 1104–21
Zhu M F et al 2015 Circumferentially aligned fibers guided functional neoartery regeneration in vivo Biomaterials 61 85–94
Wang H, Xing M M, Deng W L, Qian M, Wang F, Wang K, Midgley A C and Zhao Q 2022 Anti-sca-1 antibody-functionalized vascular grafts improve vascular regeneration via selective capture of endogenous vascular stem/progenitor cells Bioact. Mater. 16 433–50
Zhao Q L, Cui H Q, Wang J, Chen H X, Wang Y L, Zhang L D, Du X M and Wang M 2018 Regulation effects of biomimetic hybrid scaffolds on vascular endothelium remodeling ACS Appl. Mater. Interfaces 10 23583–94
Li Y Z et al 2017 Netrin-1 promotes inflammation resolution to achieve endothelialization of small-diameter tissue engineering blood vessels by improving endothelial progenitor cells function in situ Adv. Sci. 4 1700278
Lee S J, Kim M E, Nah H, Seok J M, Jeong M H, Park K, Kwon I K, Lee J S and Park S A 2019 Vascular endothelial growth factor immobilized on mussel-inspired three-dimensional bilayered scaffold for artificial vascular graft application: in vitro and in vivo evaluations J. Colloid Interface Sci. 537 333–44
Robinson T M, Hutmacher D W and Dalton P D 2019 The next frontier in melt electrospinning: taming the jet Adv. Funct. Mater. 29 1904664
Li Y R, Xie M, Lv S, Sun Y, Li Z, Gu Z and He Y 2023 A bionic controllable strain membrane for cell stretching at air–liquid interface inspired by papercutting Int. J. Extrem. Manuf. 5 045502
Chen Y W et al 2024 Gelatin-based metamaterial hydrogel films with high conformality for ultra-soft tissue monitoring Nanomicro Lett. 16 34
Xie C Q, Gao Q, Wang P, Shao L, Yuan H P, Fu J Z, Chen W and He Y 2019 Structure-induced cell growth by 3D printing of heterogeneous scaffolds with ultrafine fibers Mater. Des. 181 108092
Castilho M, Feyen D, Flandes-Iparraguirre M, Hochleitner G, Groll J, Doevendans P A F, Vermonden T, Ito K, Sluijter J P G and Malda J 2017 Melt electrospinning writing of poly-hydroxymethylglycolide-co-ϵ-caprolactone-based scaffolds for cardiac tissue engineering Adv. Healthcare Mater. 6 1700311
Brown T D, Slotosch A, Thibaudeau L, Taubenberger A, Loessner D, Vaquette C, Dalton P D and Hutmacher D W 2012 Design and fabrication of tubular scaffolds via direct writing in a melt electrospinning mode Biointerphases 7 13
Zhang F C, Cao K, Zaeri A, Zgeib R, Buckley C, Ma Y W and Chang R C 2023 Design, fabrication, and characterization of tubular scaffolds by way of a melt electrowriting process Addit. Manuf. 62 103383
van Genderen A M et al 2021 Topographic guidance in melt-electrowritten tubular scaffolds enhances engineered kidney tubule performance Front. Bioeng. Biotechnol. 8 617364
Thibaudeau L et al 2014 A tissue-engineered humanized xenograft model of human breast cancer metastasis to bone Dis. Model. Mech. 7 299–309
Baldwin J G, Wagner F, Martine L C, Holzapfel B M, Theodoropoulos C, Bas O, Savi F M, Werner C, De-Juan-Pardo E M and Hutmacher D W 2017 Periosteum tissue engineering in an orthotopic in vivo platform Biomaterials 121 193–204
Castillo-Cruz O, Pérez-Aranda C, Gamboa F, Cauich-Rodríguez J V, Mantovani D and Avilés F 2018 Prediction of circumferential compliance and burst strength of polymeric vascular grafts J. Mech. Behav. Biomed. Mater. 79 332–40
Choi S W, Zhang Y, MacEwan M R and Xia Y N 2013 Neovascularization in biodegradable inverse opal scaffolds with uniform and precisely controlled pore sizes Adv. Healthcare Mater. 2 145–54
Bai F, Wang Z, Lu J X, Liu J, Chen G Y, Lv R, Wang J, Lin K L, Zhang J K and Huang X 2010 The correlation between the internal structure and vascularization of controllable porous bioceramic materials in vivo: a quantitative study Tissue Eng. A 16 3791–803
Oh S H, Park I K, Kim J M and Lee J H 2007 In vitro and in vivo characteristics of PCL scaffolds with pore size gradient fabricated by a centrifugation method Biomaterials 28 1664–71
Song J Q, Lv B H, Chen W C, Ding P and He Y 2023 Advances in 3D printing scaffolds for peripheral nerve and spinal cord injury repair Int. J. Extrem. Manuf. 5 032008
Cao K, Zhang F C, Zaeri A, Zgeib R and Chang R C 2022 A holistic model for melt electrowritten threedimensional structured materials based on residual centerge Int. J. Bioprint. 9 656
Kim J, Bakirci E, O’Neill K L, Hrynevich A and Dalton P D 2021 Fiber bridging during melt electrowriting of poly(ϵ-caprolactone) and the influence of fiber diameter and wall height Macromol. Mater. Eng. 306 2000685
Kade J C, Otto P F, Luxenhofer R and Dalton P D 2021 Melt electrowriting of poly(vinylidene difluoride) using a heated collector Polym. Adv. Technol. 32 4951–5
Karimi A, Navidbakhsh M, Shojaei A and Faghihi S 2013 Measurement of the uniaxial mechanical properties of healthy and atherosclerotic human coronary arteries Mater. Sci. Eng. C 33 2550–4
Han F X, Jia X L, Dai D D, Yang X L, Zhao J, Zhao Y H, Fan Y B and Yuan X Y 2013 Performance of a multilayered small-diameter vascular scaffold dual-loaded with VEGF and PDGF Biomaterials 34 7302–13
Sarkar S, Salacinski H J, Hamilton G and Seifalian A M 2006 The mechanical properties of infrainguinal vascular bypass grafts: their role in influencing patency Eur. J. Vascular Endovasc. Surg. 31 627–36
Shuai C J, Yuan X, Yang W J, Peng S P, Qian G W and Zhao Z Y 2021 Synthesis of a mace-like cellulose nanocrystal@Ag nanosystem via in-situ growth for antibacterial activities of poly-L-lactide scaffold Carbohydr. Polym. 262 117937
Shuai C J, Cheng Y, Yang W J, Feng P, Yang Y W, He C X, Qi F W and Peng S P 2020 Magnetically actuated bone scaffold: microstructure, cell response and osteogenesis Composites B 192 107986
Yang W J, Zhong Y C, He C X, Peng S P, Yang Y W, Qi F W, Feng P and Shuai C J 2020 Electrostatic self-assembly of pFe3O4 nanoparticles on graphene oxide: a co-dispersed nanosystem reinforces PLLA scaffolds J. Adv. Res. 24 191–203
Shuai C, Yuan X, Shuai Y, Qian G, Yao J, Xu W, Peng S and Yang W 2022 Nitrogen-doped carbon-ZnO heterojunction derived from ZIF-8: a photocatalytic antibacterial strategy for scaffold Mater. Today Nano 18 100210
Meng Z J, Mu X D, He J K, Zhang J L, Ling R and Li D C 2023 Embedding aligned nanofibrous architectures within 3D-printed polycaprolactone scaffolds for directed cellular infiltration and tissue regeneration Int. J. Extrem. Manuf. 5 025001
Fu J Y, Wang M, De Vlaminck I and Wang Y D 2020 Thick PCL fibers improving host remodeling of PGS-PCL composite grafts implanted in rat common carotid arteries Small 16 2004133
Original content from this work may be used under the terms of the Creative Commons Attribution 4.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.