Design and Fabrication of Slidable Pedicle Screw Frame System for Surgery Therapy of Patients with Spinal Deformity in Growth Period

Zhenglei Wang( )Jichang GaoDanbing JiaWenjing ZhangPeng SunQi QiMing gongWenxian FanXianyu WuFuquan Zhao
Department of Orthopedics of No. 211 Hospital of the PLA, Harbin 150080, P. R. China
Show Author Information

Abstract

With the aim of preventing iatrogenic shot trunk, stiffness and rotation deformity caused by long-term fixation with usual locked pedicle screw system, a new kind of slidable pedicle screw frame system was designed and fabricated to treat patients with spinal deformity in the growth period. The frame was composed of slidable and locked pedicle screws, cross-links and double rods. The middle part of double rods was fixed with locked pedicle screws and two ends of them were with slidable ones. The spine longitudinal and transverse growth was not limited. 360 patients including 82 congenital scoliosis, 110 idiopathic scoliosis, 60 kyphosis, 44 spinal fractures and 63 spinal tumors or tuberculosis were treated. The average preoperative Cobb’s angle of scoliosis was 66.43°, post-operative one was 22.43°and lost 5° with average 14 months of following-up (6-37 months). The total longitudinal growth of adolescent spinal deformity was 86.4 cm (mean 0.9 cm). In conclusion, slidable pedicle screw frame system is successfully designed and fabricated, also stable and effective to correct the spinal deformities in adolescent growth period. The longitudinal and transverse spine growth of post-operation patients was not limited, and no complications such as stiffness, vertebrae rotation and crank shaft happened for post-operation patients.

References

1

Harrington PR, Dichson JH. Spinal Instrumentation in the severe progressive spondlo listhesis. Clin Orthop.1976; 117-157.

2

Raymond Roy-camile.et al.internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop.1986; 203: 7

3

Li SG, Sheng L, Zhao H, Zhang JG, Zhai JL, Zhu Y. Computerass-isited navigation technique in the spinal pedicle screw internal fixation. Journal of Clinical Rehabilitative Tissue Engineering Research 2009; 13(7): 3365-3369.

4

Qiu GX. Spinal side-convex therapy. Chinese Journal of Orthopaedics 1995; 15(0): 15-717.

5
Hu YG, Qiu GX, Tang TS. Spinal surgery. People Sanitation Press 2000; no 2 version, p377.
6

Ye QB, Qiu GX, Wang YM. Early results of PRSS’ therapy for spinal side bend of children and the young in the course of growth and development. Orthopedic Journal of China 2001; 8(1): 16-20.

7

Wen XS, Jiu GX, Zhang J. Long term therapeutic effects evaluation of inner fixation of spinal Pedicle. Chinese Journal of Orthopaedics 2001; 21(11): 64-665.

8

Dick W, et al. A new device for internal fixation of thoraco-lumbar and lumbar spine fracture: the fixation in terne. Paraplegia.1959; 23 : 225.

9

Hakalo J, Wroński J. Complications of a transpedicular stabilization of thoraco-lumbar burst fractures. Neurol Neurochir Pol. 2006; 40: 134-139.

10

Fuentes S, Blondel B, Metellus P, Gaudart J, Adetchessi T, Dufour H.Percutaneous kyphoplasty and pedicle screw fixation for the management of thoraco-lumbar burst fractures. Eur Spine J. 2010; 19(8):1281-1287. doi: 10.1007/s00586-010-1444-4

11

Steib JP, Mezghani S, Charles YP, Mitulescu A. Double approach in thoraco-lumbar malunions. Eur Spine J 2010; Suppl 1:S48-51. doi: 10.1007/s00586-009-1165-8

12

Arregui R, Martínez-Quiñones JV, Aso-Escario J, Aso-Vizan J. Vertebral reinforcement by means of kyphoplasty in the treatment of non-osteoporotic thoraco-lumbar fractures. Study of 40 cases and review of the literature. Neurocirugia (Astur). 2008; 19(6): 537-5350.

13

Fuentes S, Metellus P, Fondop J, Pech-Gourg G, Dufour H, Grisoli F. Percutaneous pedicle screw fixation and kyphoplasty for management of thoracolumbar burst fractures. Neurochirurgie. 2007; 53(4): 272-276.

14

Payer M. Unstable burst fractures of the thoraco-lumbar junction: treatment by posterior bisegmental correction/fixation and staged anterior corpectomy and titanium cage implantation. Acta Neurochir (Wien). 2006; 148(3): 299-306. doi: 10.1007/s00701-005-0681-5

15

Stulík J, Krbec M, Vyskocil T. Use of bioceramics in the treatment of fractures of the thoraco-lumbar spine. Acta Chir Orthop Traumatol Cech. 2002; 69(5): 288-94.

16

Andress HJ, Braun H, Helmberger T, Schürmann M, Hertlein H, HartlWH. Long-term results after posterior fixation of thoraco-lumbar burst fractures. Injury. 2002; 33(4): 357-365.doi: 10.1016/S0020-1383(02)00030-X

17

Changxiao Liu. Research and development of nanopharmaceuticals in China. Nano Biomed Eng 2009; 1(1):1-12. doi: 10.5101/nbe.v1i1.p1-12

Nano Biomedicine and Engineering
Pages 126-129
Cite this article:
Wang Z, Gao J, Jia D, et al. Design and Fabrication of Slidable Pedicle Screw Frame System for Surgery Therapy of Patients with Spinal Deformity in Growth Period. Nano Biomedicine and Engineering, 2011, 3(2): 126-129. https://doi.org/10.5101/nbe.v3i2.p126-129

365

Views

3

Downloads

0

Crossref

1

Scopus

Altmetrics

Published: 30 June 2011
© 2011 Z. Wang, et al.

This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Return