Publications
Sort:
Open Access Research paper Issue
Comparison study on measurement of rail weld joint between inertial reference method and multi-point chord reference method
Railway Sciences 2024, 3(1): 69-83
Published: 10 January 2024
Abstract PDF (5.9 MB) Collect
Downloads:2
Purpose

Straightness measurement of rail weld joint is of essential importance to railway maintenance. Due to the lack of efficient measurement equipment, there has been limited in-depth research on rail weld joint with a 5-m wavelength range, leaving a significant knowledge gap in this field.

Design/methodology/approach

In this study, the authors used the well-established inertial reference method (IR-method), and the state-of-the-art multi-point chord reference method (MCR-method). Two methods have been applied in different types of rail straightness measurement trollies, respectively. These instruments were tested in a high-speed rail section within a certain region of China. The test results were ultimately validated through using traditional straightedge and feeler gauge methods as reference data to evaluate the rail weld joint straightness within the 5-m wavelength range.

Findings

The research reveals that IR-method and MCR-method produce reasonably similar measurement results for wavelengths below 1 m. However, MCR-method outperforms IR-method in terms of accuracy for wavelengths exceeding 3 m. Furthermore, it was observed that IR-method, while operating at a slower speed, carries the risk of derailing and is incapable of detecting rail weld joints and low joints within the track.

Originality/value

The research compare two methods’ measurement effects in a longer wavelength range and demonstrate the superiority of MCR-method.

Total 1